I'm pretty sure there's no mocking intended here, he's just posting what happened to him with regard to a static charge. I see that the schematic at the bottom of the page (Neutral Transformer Approach) for the GFI device (from your link) contains a couple of coils which I assume sense the electromagnetic fields of the hot and neutral wires. This signal is fed to an IC which appears to have the function of controlling the relay which trips the device. The circuit is tuned to be quite sensitive so that it cuts the power with only a fraction of an amp imbalance. Any solid state device and inductance coil/transformer is susceptible to a static charge or EMI (electromagnetic interference). I'd say it's entirely possible that a static charge or EMI pulse could trip the device even if nothing is plugged into it. As long as line voltage is present at the input of the GFI device, it is sensing, whether it's actually powering something or not. If you read down farther on the page you linked to, there's a case of lightning tripping a GFI device. So IMO, there are more ways to trip these devices other than the 'designed' imbalance between line/neutral.
__________________
Mike
77g sumpless SW
DIY 10 watt multi-chip LED build http://www.canreef.com/vbulletin/showthread.php?t=82206

Last edited by mike31154; 03-20-2010 at 08:58 PM.
Reply With Quote
  #22  
Old 03-20-2010, 08:59 PM
christyf5's Avatar
christyf5 christyf5 is offline
Staff
 
Join Date: Aug 2001
Location: Nanaimo
Posts: 9,175
christyf5 is on a distinguished road
Default

I plugged the pump into a bathroom GFCI and it tripped, guess the pump is done. Anyone need a mag7 impeller?
__________________
Christy's Reef Blog

My 180 Build

Every electronic component is shipped with smoke stored deep inside.... only a real genius can find a way to set it free.
Reply With Quote
  #23  
Old 03-20-2010, 09:06 PM
mike31154's Avatar
mike31154 mike31154 is offline
Member
 
Join Date: Jul 2008
Location: Vernon
Posts: 2,073
mike31154 will become famous soon enough
Default

Oh no, not yet!! You need to liberate the smoke from deep inside of that bad boy first, ha ha.
__________________
Mike
77g sumpless SW
DIY 10 watt multi-chip LED build http://www.canreef.com/vbulletin/showthread.php?t=82206
Reply With Quote
  #24  
Old 03-20-2010, 09:07 PM
christyf5's Avatar
christyf5 christyf5 is offline
Staff
 
Join Date: Aug 2001
Location: Nanaimo
Posts: 9,175
christyf5 is on a distinguished road
Default

Quote:
Originally Posted by mike31154 View Post
Oh no, not yet!! You need to liberate the smoke from deep inside of that bad boy first, ha ha.
__________________
Christy's Reef Blog

My 180 Build

Every electronic component is shipped with smoke stored deep inside.... only a real genius can find a way to set it free.
Reply With Quote
  #25  
Old 03-20-2010, 10:24 PM
Gary Gary is offline
Member
 
Join Date: Sep 2009
Location: Prince Albert
Posts: 25
Gary is on a distinguished road
Default

Quote:
Originally Posted by DiverDude View Post
GFCI's work like this: Normally, current flows between HOT (black/larger blade of the plug) and NEUTRAL (white/smaller blade). Under normal circumstances, there is no current flow in the ground wire (green wire).

When someone somehow makes contact with either HOT or NEUTRAL, they can potential conduct (via their body) to ground. This poses a safety risk -particularly if one hand is in contact with the live wire and the other is at ground potential since the path is across the chest and there is a chance of fibrilation (this is BAD, very bad).

Enter the GFCI. It senses if there is current flow in ground. If there is, it surmises that something is not koscher and cuts power to protect the human it supposes is doing this. It's worth pointing out that GFCI's are to protect people, not the equipment. Equipment is protected by the breaker.

So.....this would imply that your pump is leaking to ground somehow -or the GFCI is faulty. I'd try plugging the pump into another GFCI and see if it pops.

Does the Mag7 have a 2-prong plug or a 3-pin (grounded) plug ? If it has a grounded plug and pops another GFCI, I'd replace the pump.

Not sure if you have a typo, but the neutral (white) should be the larger blade of the plug not the hot (black).
Reply With Quote
  #26  
Old 03-20-2010, 10:39 PM
Lance's Avatar
Lance Lance is offline
Member
 
Join Date: Feb 2008
Location: Powell River, B.C.
Posts: 3,572
Lance is on a distinguished road
Default

Quote:
Originally Posted by mike31154 View Post
Oh no, not yet!! You need to liberate the smoke from deep inside of that bad boy first, ha ha.

Good one Mike! I love it!
__________________
225g reef
Reply With Quote
  #27  
Old 03-20-2010, 10:52 PM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

Quote:
Originally Posted by outacontrol View Post
WTF!

IS THERE A REASON YOU ARE MOCKING WHAT I AM SAYING? DO YOU HAVE ANY ELECTRICAL TRAINING?
I helped you when you could not get your 3-way switching working. Not impressed at all.
Did you read any of that link that I posted? A GFCI does not function any other way than I described it measures the current on the 2 current carrying wires (the hot and the neutral that you like to call them). It does not measure or check for current on the bare bonding wire (or ground as you like to call it) at all. Period no questions about it.
Whoa there dude. Please be assured I am not mocking you. Not in the least. In fact rather the opposite, I am trying to use your electrical knowledge in an effort to better understand something I saw. I think your issue is the fact I asked if if it's hard to say. I didn't mean that as mockery, I really meant that at face value - is it hard to say if the static discharge was responsible for a GFCI trip? The reflector was most assuredly grounded, so the zap of the static absolutely did travel down the ground wire. I was merely asking if it was a possibility that GFCI's could be tripped by more than input condition.

Breathe easy my friend. I will buy you a coffee or whatever your favourite equivalent beverage may be one day should we ever meet in person. How a GFCI works is less important to me than whether they work at all. It was only curiosity on my part.

At any rate however ... regardless of how a GFCI trips, a pump shouldn't trip the GFCI. Now that it's confirmed that the pump itself seems faulty (ie., confirmed trip on a different GFCI) I'm afraid the end result for Christy is that she needs to replace her pump. Sorry Christy. FWIW, I had to garbage can a couple mag drives too over the years for the same reason. It's too bad, they are otherwise really reliable workhorses.
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!

Last edited by Delphinus; 03-20-2010 at 10:56 PM.
Reply With Quote
  #28  
Old 03-21-2010, 12:01 AM
DiverDude's Avatar
DiverDude DiverDude is offline
Member
 
Join Date: Feb 2010
Location: Calgary
Posts: 519
DiverDude is on a distinguished road
Default

*sigh* TWO errors in one post....what WILL I do with me ?

First, I stand corrected by outtacontrol. How I described the function of the GFCI was what had been taught to me by someone who should know better (an electrical engineering professor). However, schematics trump credentials and I now know better -my apologies for the mis-information !

Second, someone give a free frag to Gary for paying attention. He is correct, Neutral is the larger blade of course and I need to type slower or think faster. More mis-information; more apologies -only this time I can't blame anyone but myself.
__________________
-Mark

29 Gal Bowfront w/24" LED Lights. DIY HOB Sump (5.4 Gal) MP40. Orange Spotted Watchman Goby, 2 Clownfish and a few hermits.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 03:17 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.