![]() |
|
#1
|
|||||
|
|||||
![]() Quote:
![]() Eggcrate guard just sitting there, plus some going on right hand return side ![]() Main drain with gate valve. Secondary with ball valve. 3/4 in return on bottom and 3/4in going to 1 in. emergency line beside it. Both are 3/4in valved in side...just in case. Lots of unions, inside and out.
__________________
Doug |
#2
|
|||||
|
|||||
![]() you know I was off all day and on the north shore, could have given ya a hand.
Steve
__________________
![]() Some strive to be perfect.... I just strive. |
#3
|
|||||
|
|||||
![]() Quote:
I did it on the weekend. Today was dentist day...... ![]()
__________________
Doug Last edited by Doug; 12-17-2013 at 02:33 AM. |
#4
|
|||||
|
|||||
![]() ahh what day s it tomorrow?
Steve
__________________
![]() Some strive to be perfect.... I just strive. |
#5
|
|||||
|
|||||
![]() Cleaning lady day
__________________
Doug |
#6
|
|||||
|
|||||
![]()
__________________
![]() Some strive to be perfect.... I just strive. |
#7
|
|||||
|
|||||
![]() Quote:
this is what I think of your pluming stack...correct me if I got it wrong ![]() As long as your emergency drain in higher than both drains,that is good. your main drain should and looks like it is lower than than your secondary drain and I don't see air intake to it a it needs it unless its fully opened. your return line when ready I would face it flowing towards the lengh of your tank as one blow or a spray bar style hoovering almost under your water main tank. Silicone work looks sloppy ![]() Union on main drain is useless if adjustments is needed when testing. I would have use gate valves never ball valves as they are really pain to work with. Last is test your lines by filling the tank and test for leeks and proper drains. Now can I see more of your clams ![]() ![]() |
#8
|
|||||
|
|||||
![]() [quote=eli@fijireefrock.com;866885]this is what I think of your pluming stack...correct me if I got it wrong
![]() Quote:
Quote:
Quote:
![]() Quote:
Quote:
__________________
Doug |
#9
|
|||||
|
|||||
![]() You've got an interesting stadium rim on your tank. Can't say I've ever seen that before.
|
#10
|
|||||
|
|||||
![]() Quote:
![]() I think in the long run I still should have had Concepts just build me one. ![]() Because it was predrilled on the bottom, my overflow is on the viewing side, instead of the inside wall side. And as Eli said, sloppy work, but as I said, functional. It would be nice to have an external on that far end, facing the wall the pipes are running through. Hmm, still time I guess. ![]()
__________________
Doug Last edited by Doug; 12-17-2013 at 03:31 PM. |