Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 03-19-2012, 01:40 AM
Josh7831 Josh7831 is offline
Junior Member
 
Join Date: Mar 2012
Location: Edmonton
Posts: 12
Josh7831 is on a distinguished road
Default Used Aquarium

Hey guys,

I have just recently purchased a second hand 130g aquarium and sump with stand & Canopy for $400.

The previous owner has had it going for 10 years but had to tear it down, should i look at re sealing it or should it be fine?

Also there is three holes drilled in the tank one in each top corner of the back panel and 1 in the dead centre of the back panel. He used the top two for his overflow to the sump, and the middle one as a drain for doing water changes. Because of how i am setting this up i cannot have an automatic water changing drain so i am wondering if i can use it to plumb in my return from pump is this a bad position for a return pump? i notice a lot of people have it return at the top of the tank is there a reason for that?

Any suggestions on where to go to get more knowledge on effective plumbing systems would be great.

Thanks

Josh
Reply With Quote
  #2  
Old 03-19-2012, 01:57 AM
AaronH AaronH is offline
Junior Member
 
Join Date: Jan 2012
Location: Devon ab
Posts: 9
AaronH is on a distinguished road
Default Extra hole

The only problem with having your return at a lower point in the tank is that if your pump fails or you loose power all the water to that point will siphon back to your sump unless you use a check valve somewhere in your return line.
I could be wrong I'm also pretty new to the whole saltwater adventure
Reply With Quote
  #3  
Old 03-19-2012, 02:15 AM
subman's Avatar
subman subman is offline
Member
 
Join Date: Jan 2009
Location: Edmonton
Posts: 1,509
subman is on a distinguished road
Default

That's exactly it. In the case of a power outage you don't want your tank to empty onto the floor.

IMO the tank should be fine as is but I always do a test fill on tanks in a place that can get wet ie. garage, lawn ect. just in case something is weak and gets weaker during the move.
__________________
225gal dt with 100g sump. Mitras, vortechs, bubble king, AI Sol and Profilux.
http://www.canreef.com/vbulletin/sho...threadid=84782
Will trade subs for frags

My other summer hobby:
http://www.edkra.ca
Reply With Quote
  #4  
Old 03-19-2012, 03:07 AM
tim the toolman tim the toolman is offline
Member
 
Join Date: Feb 2011
Location: Edmonton
Posts: 396
tim the toolman is on a distinguished road
Default

Check valve and you should be fine. Just remember when calculating for a return pump you will lose some flow rate due to the check valve, but not a large percentage.
Seal should be fine, but if you want peace of mind it never hurts to use the opportunity to reseal an older tank, who knows how long before you get this chance again.
Reply With Quote
  #5  
Old 03-19-2012, 03:22 AM
subman's Avatar
subman subman is offline
Member
 
Join Date: Jan 2009
Location: Edmonton
Posts: 1,509
subman is on a distinguished road
Default

sorry mis-read your post. check valve and good to go! as tim said
__________________
225gal dt with 100g sump. Mitras, vortechs, bubble king, AI Sol and Profilux.
http://www.canreef.com/vbulletin/sho...threadid=84782
Will trade subs for frags

My other summer hobby:
http://www.edkra.ca
Reply With Quote
  #6  
Old 03-19-2012, 04:53 AM
Josh7831 Josh7831 is offline
Junior Member
 
Join Date: Mar 2012
Location: Edmonton
Posts: 12
Josh7831 is on a distinguished road
Default

The tank came with a 2000gph pump, i am not sure if that would be way to strong considering im using two 1" overflow pipes, and it only has 4' head.

It also came with a four stage modular filter, mechanical, chemical, heater & UV light, should i use this? can that be setup to the 2000gph pump?

so it would be, Sump>4pt filter>check valve>tank?

theres so many parts that came with this and im very new

Thanks guys!

Josh
Reply With Quote
  #7  
Old 03-19-2012, 05:06 AM
tim the toolman tim the toolman is offline
Member
 
Join Date: Feb 2011
Location: Edmonton
Posts: 396
tim the toolman is on a distinguished road
Default

Definitely not too much flow. I am using a 3200gph return and would consider going bigger once this one craps out. I just used locline and a splitter to make my 2 return lines put out from 4 points.
Reply With Quote
  #8  
Old 03-19-2012, 05:11 AM
Josh7831 Josh7831 is offline
Junior Member
 
Join Date: Mar 2012
Location: Edmonton
Posts: 12
Josh7831 is on a distinguished road
Default

Not too much flow for the filtration system?

I thought i red that 1" pipe would be about 600 gph, so 2 of them is 1200 if im using a 2000gph pump back to the tank would that not overflow my tank? or am i miss informed.

thanks
Reply With Quote
  #9  
Old 03-19-2012, 05:14 AM
lockrookie's Avatar
lockrookie lockrookie is offline
Member
 
Join Date: Dec 2009
Location: regina
Posts: 1,535
lockrookie is on a distinguished road
Default

if you plan your plumbing is such a way that the return in behind the tank goes higher than the water level from sump then back down to the centre hole you can use a T and instal a hose for syphon break simular to what i did on my 50g my return is lower in the tank.. if you need ore pics just ask

__________________
Desperately seeking serenity ...
180g custom build
http://www.canreef.com/vbulletin/showthread.php?t=81400

50g custom daycare tank...
http://www.canreef.com/vbulletin/showthread.php?t=65428
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 06:59 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.