#1
|
|||||
|
|||||
![]() The tank is a 650g and not to sure on the sump but i'm guessing a 70-90g sump. The tank is a hex with a center overflow. Yes there is a skimmer a bubble king 300 i think. As for overflow levels, I'm not really sure but i'll ask the owner to keep an eye on it.
|
#2
|
|||||
|
|||||
![]() Well I can't believe u guys haven't figured it out yet it's the skimmer take it out and send it to me. Hehehehhhe sorry had to say it. A picture will help out alot to see
__________________
180 starfire front, LPS, millipora Doesn't matter how much you have been reading until you take the plunge. You don't know as much as you think. |
#3
|
|||||
|
|||||
![]() two things come to mind, one do they have an well meaning employ who notices it is getting low and tops it up?
and the second is maybe there is some syphoning going on.. do they run the skimmer 24/7 or does it shut off at times, is the overflow level slowly building up then creating a syphon effect when its all water and drawing down more than normal? as for temp.. nop not going to notice the expansion of water.. might make a milimeter difference but not realy noticable as the tank water with heaters and such should stay fairly constant in temp. Steve
__________________
![]() Some strive to be perfect.... I just strive. |
#4
|
|||||
|
|||||
![]() Quote:
![]() Steve
__________________
![]() Some strive to be perfect.... I just strive. |
#5
|
|||||
|
|||||
![]() i think you need to replace that skimmer, i have one for trade H&S 1260 200A
dont worry, ill help you out and make a even trade |
#6
|
|||||
|
|||||
![]() my sump did that to me once something clogged the overflow temporarily then it took off and went normal. so i say a plumbing prob maybe a snail in overflow turns one way its ok turns another and stops the flow.... or water gremlins all the same inthe end
__________________
Desperately seeking serenity ... 180g custom build http://www.canreef.com/vbulletin/showthread.php?t=81400 50g custom daycare tank... http://www.canreef.com/vbulletin/showthread.php?t=65428 |
#7
|
|||||
|
|||||
![]() I'm thinking the same sort of thing lockrockie is suggesting. Barring the possibility that someone might be topping up that you don't know about, it sounds more like to me that the speed of water in the overflow pipe is not steady state. If it speeds up the main tank drains faster until it reaches steady-state again (but by then it's lowered in the main tank, and we could be talking a minuscule amount for the level to lower for it to be substantial in the sump), and more water ends up in the sump. If it slows down the main tank drains slower until again steady-state is found and now the sump is low.
Things that can cause speed to change in the overflow plumbing are things like excessive bends that are prone to clogging (ie., snail in the pipe or whatnot), or even if the outflow pipe is submerged, it could be building up backpressure. Is there any "burping" happening where water enters the sump?
__________________
-- Tony My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee! |
#8
|
|||||
|
|||||
![]() Another Oddball suggestion, but depending on how the restaurant's wired there could be a voltage drop when the lights and everything else are on in the tank, and also the restaurant. There's obviously building codes that would provide sufficient wiring with no more than 5% drop, but... if the tanks pigtailed off another circuit that's feeding something else, there actually could be 10%+ drop, reducing the output of the return pump.
I had this happen with 2 portable AC's plugged in to the same circuit as my tank, also finding out that 15A breakers can take a little more than what they say haha. But my water level in my tank was changing by 1/2 an inch when the AC was on, and off again the water would come back up. Turns out i had 102V at the receptical, and 112 with just the tank. This is >5%, and also in a new house, which should be to electrical code. I agree with the others, probably a plumbing issue, but an easy test if you have a multimeter.
__________________
My 150 In Wall Build |
#9
|
|||||
|
|||||
![]() I don't know that I have said this before but..................... PLUMBING PROBLEM....................I have seen this tank in person once and got a quick look at the gut's and did not like what I saw. There was to much piping there for how simple the set up really is. Return line's are coming out of the overflow, there was a TON of hair algea at the top all around the overflow. I could not tell what the overflow consisted of because the resturaunt was open and I don't think the owner would have been to happy with me if I got down on the floor and got right into the sump area to check it all out. I did not really see a proper ATO, there is a second holding tank that is under the MD for RO water holding and it is plumbed at the bottom of the RO tank to the bottom of the sump.
Just my 2 cent for what it is worth.
__________________
Feed the bear goodies, make a new friend, don't feed the bear............... 8' - 165gal Reef DIY LED's Build 2012 Nano Contest Winner Febuary 2013 POTM Winner 300 gal + 60 gal Complete DIY Build |
#10
|
||||
|
||||
![]() He just wants to try out another different skimmer. After thinking about it I think
StirCrazy has hit the nail on the head.... Bill Last edited by bvlester; 09-26-2010 at 05:38 AM. |