Quote:
Originally Posted by trilinearmipmap View Post
I'm going to re-plumb my tank after many years. I wanted to know people's experience with unions.

So far I have only had unions on drain lines which are over the sump, in case of a leak it would drip into the sump. None have leaked though.

I am looking at adding a couple of unions to the return line for ease of access, and these would be in the back of the tank. A leak would be a minor disaster.

Just wondering if people have experience on leaking or non-leaking of return lines which are under pressure.
I have unions on my return PVC piping to be able to take my check valve out for cleaning and it's never been a problem, just don't over tighten them. Do up hand tight then 1/8- 1/4 turn more with channel lock pliers.
__________________
Hey! I never "LEFT" the hobby, just doing fresh water now. Which is still listed as part of Canreef if I'm not mistaken.
Reply With Quote
  #2  
Old 01-12-2014, 01:09 PM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

O-rings will deform. No problem leaking if left alone but if in a few years you take things apart might nice to have new ones available for when you re-assemble.

Last time cleaned CL pump noticed them rather flat, not leaking but took measurements to have next time.
__________________
my tank
Reply With Quote
  #3  
Old 01-12-2014, 02:33 PM
Madreefer's Avatar
Madreefer Madreefer is offline
Member
 
Join Date: Nov 2008
Location: Prince George
Posts: 2,064
Madreefer is on a distinguished road
Default

Quote:
Originally Posted by The Guy View Post
I have unions on my return PVC piping to be able to take my check valve out for cleaning and it's never been a problem, just don't over tighten them. Do up hand tight then 1/8- 1/4 turn more with channel lock pliers.
That's how I tightened one a long time ago and I broke the bond where it was glued on. But I did'nt use primer. As for the o-ring seal i've never had a problem. It's actually a good idea to use unions on external return pumps in case your pump or pump seal goes, much easier than having to cut your plumbing.
Reply With Quote
  #4  
Old 01-12-2014, 05:16 PM
1eyedjyde 1eyedjyde is offline
Member
 
Join Date: Mar 2009
Location: Prince George
Posts: 112
1eyedjyde is on a distinguished road
Default

its always a good plan to use unions around the wear items on your plumbing ie pumps, check valves, wave devices. It makes maintenance possible without having to dismantle your plumbing.
Reply With Quote
  #5  
Old 01-12-2014, 05:24 PM
asylumdown's Avatar
asylumdown asylumdown is offline
Member
 
Join Date: Jan 2010
Location: Calgary
Posts: 1,806
asylumdown is on a distinguished road
Default

Quote:
Originally Posted by 1eyedjyde View Post
its always a good plan to use unions around the wear items on your plumbing ie pumps, check valves, wave devices. It makes maintenance possible without having to dismantle your plumbing.
+1, my pump would be unserviceable without them. The only problem I have had has been some slow salt creep around where the union joined the flex tube piping. I solved that by smothering the seam in aquarium silicone. I'll never be able to get half the union off the pipe, but all I really care about is being able to get the pump out for cleaning.
Reply With Quote
  #6  
Old 01-12-2014, 06:54 PM
The Guy The Guy is offline
busy with fresh water.
 
Join Date: Dec 2011
Location: Kelowna, BC
Posts: 1,041
The Guy is on a distinguished road
Default

Quote:
Originally Posted by Madreefer View Post
That's how I tightened one a long time ago and I broke the bond where it was glued on. But I did'nt use primer. As for the o-ring seal i've never had a problem. It's actually a good idea to use unions on external return pumps in case your pump or pump seal goes, much easier than having to cut your plumbing.
I guess me being an HVAC mechanic by trade I forget and assume people would use a hold back on the stationary glued part of the union, also some O-ring lube is good idea on unions.
Hey Bill your new DT looks awesome!
__________________
Hey! I never "LEFT" the hobby, just doing fresh water now. Which is still listed as part of Canreef if I'm not mistaken.
Reply With Quote
  #7  
Old 01-13-2014, 01:11 AM
Madreefer's Avatar
Madreefer Madreefer is offline
Member
 
Join Date: Nov 2008
Location: Prince George
Posts: 2,064
Madreefer is on a distinguished road
Default

Quote:
Originally Posted by The Guy View Post
I guess me being an HVAC mechanic by trade I forget and assume people would use a hold back on the stationary glued part of the union, also some O-ring lube is good idea on unions.
Hey Bill your new DT looks awesome!
Hey thanks bud.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 04:50 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.