#1
|
|||||
|
|||||
![]() Quote:
These units have a booster pump mine runs 130 ISh, also have auto back flush and a few other features, all in all about 3 or 4 solenoids on top of a normal unit.
__________________
360 gallon sps reef, 180 gal sump, bubble king supermarine 300, 4xmp40Wes, 2 x 6215 tunze waveboxes, 4 ghl mitras 360 Reef Tank |
#2
|
|||||
|
|||||
![]() Quote:
http://www.buckeyehydro.com/faq/#Q12...br><p><a href= Again, I don't own a Vertex, sure seems like 3 solenoids would make things much more complex. Had a look at your photos & almost impossible to troubleshoot something like this with all that plumbing running behind the cartridges. But I did notice the T fitting at the front of your prefilter and that makes no sense to me? Any instructions come with the unit? If not, contacting the good people at Vertex may be your best bet for a solution to the issue.
__________________
Mike 77g sumpless SW DIY 10 watt multi-chip LED build ![]() |
#3
|
|||||
|
|||||
![]() can you hear the pumps or solenoids trigger? do the indicator lights tell any information?
i know there was a batch of units that had a faulty solenoid, and once replaced, it worked flawlessly. but that was several months ago. |
#4
|
||||
|
||||
![]() I can hear the pump running. The lights make it look like everything is running correctly. Source water light is on, Making water light is on.
__________________
75 Gal. display with 40 Gal sump - Dual 1.5" drains, Aragonite sugar sand substrate, SWC Extreme 250 Cone Protein Skimmer, 1800L return pump, 4 AI SOL LED Lights, 250 ml pellets in a recirculating bio-pellet reactor, BRS Doser pumps for Calc & Alk, Tunze Osmolator Auto Topoff system connected Vertex Puratek RO/DI. |
#5
|
||||
|
||||
![]() Ok I found the problem. The 90° fitting going into the RO canister is not allowing water to pass. There is a small metal valve built into the fitting that remains closed. If I push on the metal disc at the bottom of the fitting it will open and then allows water to flow. With water pressure on the fitting the small metal valve remains closed. It seems like if there was pressure inside the RO canister that the inside pressure might open the valve allowing the water to flow, but how do you get pressure inside the canister if the valve is closed. Is this small valve required? What if I replaced the fitting with another fitting without a valve?
I have attached a couple pictures. ![]() ![]()
__________________
75 Gal. display with 40 Gal sump - Dual 1.5" drains, Aragonite sugar sand substrate, SWC Extreme 250 Cone Protein Skimmer, 1800L return pump, 4 AI SOL LED Lights, 250 ml pellets in a recirculating bio-pellet reactor, BRS Doser pumps for Calc & Alk, Tunze Osmolator Auto Topoff system connected Vertex Puratek RO/DI. |
#6
|
||||
|
||||
![]() I pulled the RO canister fittings off and found that the fitting going to the waste line did not have this small check valve on it but the fitting for the produced water did have a check valve built into the fitting. I swapped the fittings around so now both my waste line and produced water line have check valves and my inlet water source does not have a check valve. Everything seems to be working fine.
My guess is that the fitting for source water is not supposed to have a check valve and someone screwed up in the assembly of my unit. All is well now and it appears that I am going to like this unit. Thanks for all the help. It was much appreciated.
__________________
75 Gal. display with 40 Gal sump - Dual 1.5" drains, Aragonite sugar sand substrate, SWC Extreme 250 Cone Protein Skimmer, 1800L return pump, 4 AI SOL LED Lights, 250 ml pellets in a recirculating bio-pellet reactor, BRS Doser pumps for Calc & Alk, Tunze Osmolator Auto Topoff system connected Vertex Puratek RO/DI. |
#7
|
|||||
|
|||||
![]() Good job ! Yet to see that
__________________
360 gallon sps reef, 180 gal sump, bubble king supermarine 300, 4xmp40Wes, 2 x 6215 tunze waveboxes, 4 ghl mitras 360 Reef Tank |