![]() Yeah I believe outlets 4 and 8 have triac relays I think ?? Trying to find some pages in it I have an older controller but trying to set up the self cleaning head but can't remember when I had read that.
__________________
360 gallon sps reef, 180 gal sump, bubble king supermarine 300, 4xmp40Wes, 2 x 6215 tunze waveboxes, 4 ghl mitras 360 Reef Tank |
#2
|
|||||
|
|||||
![]() 1,2,3,5,6,7 outlets are TRIACS. Which have what is called Leakage current. They are allways on so to speak. They need a larger load connected to them to be acctually OFF. It's quite common actually. Everyting in industrial control is like that. A lot of times, with a LED indicator light or something, we need to put a resistor in with it in parallel to load the output so that it draws the leakage current down.
Swapping your pump to 4 or 8 outlet will solve it. They are true dry contact relay outputs