Default ATO diluting salinity

On my 90 gallon system with herbie overflow I have been having issues where I cannot seem to match water coming down the drain with water going up into the display. The fluctuating water level in the return section of my sump is causing premature top off and is, therefore, diluting my salinity. Is there any solution to this?

Im running a JBJ Auto Top off system with a Aqualifter pump and my float switch is located in the return section.

Has anybody else had this problem? Any insight would be appreciated, thanks!
__________________
Wayne

Rainforest of the Sea
First 90g Reef
Reply With Quote
  #2  
Old 04-19-2012, 12:09 AM
daniella3d's Avatar
daniella3d daniella3d is offline
Member
 
Join Date: Jun 2010
Location: longueuil, quebec
Posts: 1,979
daniella3d is on a distinguished road
Default

Something seem not right with your setup. I have 2 JBJ auto top off and never had a problem with any of them.

Why is the water level fluctuate in your sump???

Whenever I do water change or maintenance I turn my top off offline so that it does not continue to fill up fresh water.

Quote:
Originally Posted by wmcinnes View Post
On my 90 gallon system with herbie overflow I have been having issues where I cannot seem to match water coming down the drain with water going up into the display. The fluctuating water level in the return section of my sump is causing premature top off and is, therefore, diluting my salinity. Is there any solution to this?

Im running a JBJ Auto Top off system with a Aqualifter pump and my float switch is located in the return section.

Has anybody else had this problem? Any insight would be appreciated, thanks!
__________________
_________________________
More fish die from human stupidity than any other disease...
Reply With Quote
  #3  
Old 04-19-2012, 12:14 AM
tim the toolman tim the toolman is offline
Member
 
Join Date: Feb 2011
Location: Edmonton
Posts: 396
tim the toolman is on a distinguished road
Default

Sounds like your overflow downpipe is not large enough to handle the volume your return pump is pushing.
How long has this been an issue?
Is it possible you have the ato control in the wrong section of your sump?
Reply With Quote
  #4  
Old 04-19-2012, 12:19 AM
toytech's Avatar
toytech toytech is offline
Member
 
Join Date: Oct 2010
Location: edmonton
Posts: 672
toytech is on a distinguished road
Default

my durso overflow would do the same thing , i had 2 1 inch drains and a 500gph return and if i didnt tune the drains with air intake and choke valves they would pull full siphon and drain the overflow box then lose siphon and the return would pump the retun section way down . So you might just have to fiddle with it a bit.
Reply With Quote
  #5  
Old 04-19-2012, 12:47 AM
philg3 philg3 is offline
Member
 
Join Date: Jun 2011
Location: Vancouver - West End
Posts: 99
philg3 is on a distinguished road
Default

Do you have a Gate Valve? The Herbie takes some fine adjusting to exactly match the full siphon flow rate to your return rate. Once dialed in it should be steady.
__________________
Reply With Quote
  #6  
Old 04-19-2012, 01:08 AM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

even with a gate valve it's just slight adjustments to get flow balanced. Once that's sorted out shouldn't have to worry about your ATO
__________________
my tank
Reply With Quote
  #7  
Old 04-19-2012, 02:37 AM
paddyob's Avatar
paddyob paddyob is offline
Member
 
Join Date: Oct 2008
Location: Edmonton
Posts: 2,481
paddyob is on a distinguished road
Default

Quote:
Originally Posted by daniella3d View Post
Something seem not right with your setup. I have 2 JBJ auto top off and never had a problem with any of them.

Why is the water level fluctuate in your sump???

Whenever I do water change or maintenance I turn my top off offline so that it does not continue to fill up fresh water.
Agreed something is not set right.


Quote:
Originally Posted by tim the toolman View Post
Sounds like your overflow downpipe is not large enough to handle the volume your return pump is pushing.
How long has this been an issue?
Is it possible you have the ato control in the wrong section of your sump?
Should be irrelevant. Unless he is never stopping the ATO, the water would mix completely within a relatively short amount of time.

I would say maybe your salt level was wrong to begin with. Perhaps your refractometer needs calibration, or in the case of float style, maybe it's off by several points like mine was before I tossed it.
__________________


My 70 Gallon build:

http://www.canreef.com/vbulletin/showthread.php?t=66478


My Mandarin Paradise:

http://www.canreef.com/vbulletin/showthread.php?t=72762



I wonder... does anyone care enough to read signatures if you make them really small? I would not. I would probably moan and complain, read three words and swear once or twice. But since you made it this far, please rate my builds.
Reply With Quote
  #8  
Old 04-19-2012, 03:01 AM
philg3 philg3 is offline
Member
 
Join Date: Jun 2011
Location: Vancouver - West End
Posts: 99
philg3 is on a distinguished road
Default

Quote:
Originally Posted by mark View Post
even with a gate valve it's just slight adjustments to get flow balanced. Once that's sorted out shouldn't have to worry about your ATO
I meant if he does not have a gate valve and only a ball valve it will be very hard to make those slight adjustments. The Gate Valve makes life infinitely easier to find the sweet spot compared to the 1/4 turn ball valves.
__________________
Reply With Quote
  #9  
Old 04-19-2012, 03:32 AM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Wayne, I haven't setup my new Tunze ATO yet, but I remember reading in the manual that there is more than one way to set the on/off pump level by spacing the sensors further apart.
Have you checked your's to see if you can have the leeway you need?
Reply With Quote
  #10  
Old 04-19-2012, 06:21 AM
wmcinnes's Avatar
wmcinnes wmcinnes is offline
Member
 
Join Date: Jan 2012
Location: Edmonton
Posts: 338
wmcinnes is on a distinguished road
Default

I have a gate valve on the drain pipe, not a ball valve. The herbie causes the level in the sump to fluctuate very very slowly but still enough to cause the ATO to turn on. Im assuming i just need to spend more time dialing it in and getting the flows to match up, thanks philg3.

I have a refractometer and it reads 1.025 after a waterchange and then a day later the salinity will be 1.024 or 1.023 so that rules out my refractometer needing calibration..

I don't think I can adjust much with this system. Its just a single float switch that turns a pump on when the float drops and turns it off when the float rises up. Maybe I will have to spend some more money and get a more elaborate system. The JBJ ATO is fairly cheap ($70).
__________________
Wayne

Rainforest of the Sea
First 90g Reef
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 11:18 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.