Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 03-21-2012, 12:29 AM
fishytime's Avatar
fishytime fishytime is offline
Member
 
Join Date: Mar 2007
Location: E-town
Posts: 5,390
fishytime will become famous soon enough
Default

Quote:
Originally Posted by Davidbugera View Post
Having it threw the front of the over flow is not a good idea in my opinion just cause if u use lock line the links don't seal together proply and If u have a power failure water will drain to the level of the bulk head I found this out by dumping 7ish gallons of water on my upstairs floor lol. I guess if u use a really good check valve it would bee ok but the ones for lock line suck
yup.....got a double siphon break.....loc-line is curved up almost at the surface of the water and I have a couple holes drilled in the elbow inside the overflow.....that and my sump is designed to handle the drainage
__________________
260g mixed reef, 105g sump, water blaster 7000 return, Bubble King SM 300 skimmer, Aqua Controller Jr, 4 radions, 3 Tunze 6055s,1 tunze 6065, 2 Vortech MP40s, Vortech MP20, Tunze ATO, GHL SA2 doser, 2 TLF reactors (1 carbon, 1 rowa). http://www.canreef.com/vbulletin/showthread.php?t=50034 . Tank Video here http://www.vimeo.com/2304609 and here http://www.vimeo.com/16591694
Reply With Quote
  #2  
Old 03-21-2012, 01:18 PM
reefgirl189's Avatar
reefgirl189 reefgirl189 is offline
Member
 
Join Date: Nov 2011
Location: Bonnyville, Alberta
Posts: 601
reefgirl189 is on a distinguished road
Default



As you can kind of see, the emergency is tee'd into the main drain line. I wish this would have been on its own drain line because tuning this herbie in for silence is very difficult when the sump is in the basement. Sometimes gravity pulls air through the emergency line when draining through the normal drain line, creating a loud air suction noise. It was very finicky to tune and as soon as the sump level changes by mere millimeters it starts all over again (thanks for ATO I don't normally have to mess with it)

Please note that there are ABS fittings on the drain line. It's not ideal. You want to choose either PVC or ABs and not interchange them but because this is only a drain line it's not that big of a deal (it's not under pressure).

Here's the sump before we fired everything up:



Since this pic we've added a check valve on the return line. This prevents water from back syphoning through the return lines in the main display in case of power loss.


Here's how we covered up the drain lines:
Reply With Quote
  #3  
Old 03-24-2012, 01:33 AM
habs247's Avatar
habs247 habs247 is offline
Member
 
Join Date: Feb 2012
Location: Calgary
Posts: 67
habs247 is on a distinguished road
Default thank you!

Ok thanks everyone. I really appreciate it.

Tank is being delivered tomorrow (supposedly). So a friend is coming over tomorrow evening and we're going to try our hand at plumbing it. No previous experience (with either plumbing or keeping a reef tank!).

If anyone can point to a good start to finish herbie tutorial, I would appreciate it. Something like the BRS video but with a bit more detail.

I'm also a little lost of how to plumb into the sump. And as my question that started this thread proved, also a little lost on the return line plumbing!

Thanks guys!
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 01:55 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.