10X turnover is enough for LPS only. You can do more but going over 20X may actually cause problems but it does really depend on tank size, layout and flow velocity.
Reply With Quote
  #2  
Old 02-23-2012, 11:23 PM
The Grizz's Avatar
The Grizz The Grizz is offline
Member
 
Join Date: Oct 2009
Location: 15 min NE of Red Deer
Posts: 5,470
The Grizz will become famous soon enough
Default

I have 3600 GPH on my closed loop on the 165gal, 4 returns though an OM 4way.
__________________
Feed the bear goodies, make a new friend, don't feed the bear...............

8' - 165gal Reef
DIY LED's Build
2012 Nano Contest Winner
Febuary 2013 POTM Winner
300 gal + 60 gal Complete DIY Build
Reply With Quote
  #3  
Old 02-23-2012, 11:28 PM
randy123 randy123 is offline
Member
 
Join Date: Nov 2009
Location: Lloydminster, AB
Posts: 75
randy123 is on a distinguished road
Default

What types of problems with higher flow might you expect? I am planning on mainly lps, but I would like to leave the door open for a few easier to keep sps if i can.

I was considering a dart pump on an OM 4 way, tank not as big as Grizz's though, its about 130 gallons (5')
Reply With Quote
  #4  
Old 02-23-2012, 11:32 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Many LPS do better in lower flow, many if subjected to SPS type flow requirements won't open and expand fully and do poorly as a result. With a closed loop you can point flow upwards towards higher portions of the rock work that could contain SPS and LPS will do well below. Also keep in mind if your pump is rated at 3600 GPH and you run it through an OM and typical tight closed loop plumbing you'll probably see closer to 2000 GPH if that. Closed loops don't have static head but do typically have more restrictive plumbing, especially on the intake which has the greatest effect.

Last edited by sphelps; 02-23-2012 at 11:35 PM.
Reply With Quote
  #5  
Old 02-23-2012, 11:59 PM
randy123 randy123 is offline
Member
 
Join Date: Nov 2009
Location: Lloydminster, AB
Posts: 75
randy123 is on a distinguished road
Default

I'm thinking of plumbing with spa flex after the OM, I think the discharge side with be completely free of 90s. I was thinking twin 1 1/2 inch lines going to a 2 inch header for the suction, one I can make straight down to the pump, the other will have a couple bends and a few foot horizontal run.

Do you know how much flow restriction occurs in the OM itself?

I like the idea of some slower spots for the lps at he bottom, as long as the gunk in the water will stay in suspension.
Reply With Quote
  #6  
Old 02-24-2012, 12:06 AM
fencer's Avatar
fencer fencer is offline
Member
 
Join Date: Aug 2007
Location: Ed Ab
Posts: 1,331
fencer is on a distinguished road
Default

80 % closed loop circ
Reply With Quote
  #7  
Old 02-24-2012, 12:47 AM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

For the intake you'll want dual 2" lines, not 1.5" if you're running a dart. Large strainers are key as that can be the biggest problem for restriction.

The amount the OM will restrict your flow will depend on the original flow rate but I find then pretty restrictive overall, I'm considering removing mine for this reason plus the timing motor tends to squeak, the drum jams up sometimes and it's a pain to maintain in tight spaces.

Personally if it were me I'd skip the OM and but two pumps instead. Plumb one pump to pull water from one side of the tank and push water in the other side. Plumb the second pump the same but opposite. Then use couple timers or a single timer and a NC+NO relay to switch between the pumps every hour or so. This way you get true alternate flow, less restriction and redundancy.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 03:57 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.