#1
|
||||
|
||||
|
You'll want to remove the 3 DI filters from their clips and orient each of them vertically so that flow through them goes from the bottom to the top.
Horizontal DI filters are a fundamental configuration error... Russ Last edited by Buckeye Field Supply; 01-13-2012 at 03:12 PM. |
|
#2
|
|||||
|
|||||
|
So your first sentence should read to orient the DI filters "vertically", vice horizontally?
__________________
Mike 77g sumpless SW DIY 10 watt multi-chip LED build |
|
#3
|
||||
|
||||
|
Agghh! Thanks - I fixed my post. |
|
#4
|
|||||
|
|||||
|
Ya, couldn't let that one slip by... I know, it's early in the morning still out west here.
__________________
Mike 77g sumpless SW DIY 10 watt multi-chip LED build |
|
#5
|
|||||
|
|||||
|
Thanks for stopping on the thread Russ! Axial flow makes a lot of sense. I noticed that CGAC cartridges were axial, but didn't register the significance of this.
|
|
#6
|
|||||
|
|||||
|
Got a kit today. It is called AquaChek Select which tests for free chlorine, total chlorine, total hardness, total bromine, pH, tota alkalinity, and cyanuric acid. It was $28 for 50 test strips. I got it at a Hottub store, but had to go to three before I found a kit that would test total chlorine.
My tap water tested chlorine 0, and total chlorine 0.5-1 ppm. RODI water tested 0 for both. So, good news is no chloramines are getting through my RODI system. Maybe my system is doing just fine... |
|
#7
|
||||
|
||||
|
Check to see if ammonia, a byproduct of chloramine treatment, is getting through your DI.
Russ |