hey,

a while back i was looking for some quick connect fittings to make extension cords for my MH ballasts.

well i found some, and tried to put them together myself, and well... i did a hack job.

plugging them in trips the GFCI.

was wondering if there was an electrician among us that could help me out putting these extensions together.

of course i would compensate you, some pocket change for an easy job, or frags if i have something you want.

just let me know, thanks!
__________________
- S H A O -
Reply With Quote
  #2  
Old 08-19-2011, 12:45 PM
reefermadness's Avatar
reefermadness reefermadness is offline
Member
 
Join Date: Aug 2008
Location: Woodstock, ONTARIO
Posts: 849
reefermadness is on a distinguished road
Default

I'm not an electrician but what are the colours you are trying to match up?
Reply With Quote
  #3  
Old 08-19-2011, 01:03 PM
wingedfish wingedfish is offline
Member
 
Join Date: Sep 2010
Location: Medicine Hat
Posts: 112
wingedfish is on a distinguished road
Default

white to the silver screw, black to the copper one and green to the green one
Reply With Quote
  #4  
Old 08-19-2011, 01:39 PM
reefermadness's Avatar
reefermadness reefermadness is offline
Member
 
Join Date: Aug 2008
Location: Woodstock, ONTARIO
Posts: 849
reefermadness is on a distinguished road
Default

Quote:
Originally Posted by wingedfish View Post
white to the silver screw, black to the copper one and green to the green one
You just explained an outlet...he is trying to put two cables together I believe.

If they have the same colour wires (ie.black,white,green) than simple logic is to just match them up.....if they have different colours well than its a little more complicated.
Reply With Quote
  #5  
Old 08-19-2011, 02:27 PM
davefrombc davefrombc is offline
Junior Member
 
Join Date: Oct 2010
Location: About 10 miles east of Mission, BC
Posts: 7
davefrombc is on a distinguished road
Default

It depends on the fixture but normally the colours coming from a unit are black , white and green. If you are tripping a GFI, I suspect you have the neutral wire ( normally white and to the silver screw on a plug or socket ) and the safety ground ( normally green , but may be a bare wire in some fixtures with wires meant to go to a box rather than an extension cord) switched. Power wire goes to the bronze screw in a plug or socket on an extension cord or wall socket .
Reply With Quote
  #6  
Old 08-19-2011, 06:12 PM
smokinreefer's Avatar
smokinreefer smokinreefer is offline
Gold Member
 
Join Date: Aug 2001
Location: burnaby,bc,canada
Posts: 1,438
smokinreefer is on a distinguished road
Send a message via MSN to smokinreefer
Default

yes, the cord has black, white and green.
it's been a couple weeks since i attempted this, i'll open them up and take a look at what mess i gone done! lol.

thanks for the input. i'll get back to you guys!
__________________
- S H A O -
Reply With Quote
  #7  
Old 10-01-2011, 02:07 AM
smokinreefer's Avatar
smokinreefer smokinreefer is offline
Gold Member
 
Join Date: Aug 2001
Location: burnaby,bc,canada
Posts: 1,438
smokinreefer is on a distinguished road
Send a message via MSN to smokinreefer
Default

so i finally had a chance to check out my wiring, and noticed that i had some wires inverted... because when you put the male and female ends together they were opposite.

so i switched those and thought that i had solved my problems.

they still trip the GFCI. please tell me what i've done wrong!

heres a pic of the wiring, male and female connected together, but with the covers off.

__________________
- S H A O -
Reply With Quote
  #8  
Old 10-01-2011, 02:46 AM
Deaner Deaner is offline
Junior Member
 
Join Date: Apr 2011
Location: Ontario
Posts: 2
Deaner is on a distinguished road
Default

There is nothing wrong with that, the question might be, what are you plugging in?
Reply With Quote
  #9  
Old 10-01-2011, 03:57 AM
Magma Magma is offline
Member
 
Join Date: Oct 2010
Location: Calgary, AB
Posts: 341
Magma is on a distinguished road
Default

The MH probably draw to much amperage when you first turn them on, which cause the GFCI to pop just as if you had a short, water in it etc. It happens to me all the time when I use HOT5's on my GFCI plug.
__________________
Reply With Quote
  #10  
Old 10-01-2011, 04:29 AM
cyberdude47 cyberdude47 is offline
Member
 
Join Date: Jul 2008
Location: Prince George
Posts: 59
cyberdude47 is on a distinguished road
Default

I'm a electrician. You can pm me with what your trying and I can try to help u out. Gfci's can trip for numerous reasons. Some ballasts leak current and can cause a premature trip. It only takes 7 thousands of a amp to trip when it sees a difference in current between the hot and neutral.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 03:46 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.