I'm on the 2-part dosing bandwagon again myself but I think the key to Dez's ease of use is the controller. That's the other thing I would use if I ever were go to a calcium reactor again (although I wouldn't , but if I did, I'd want a pH controller)

One cautionary note about T'ing off the sump return like what has been described above: the flowrate should be controlled at the inlet side of the reactor (ie., like how Mark has shown, the valve must be between the sump return pipe and the reactor ... not on the output side of the reactor). The reason for this is that sump return pumps might be capable of producing enough pressure inside the reactor that the acrylic seams and the flange are under more stress. I actually blew up a reactor doing this (weak seam I guess, I don't think that's typical, but certainly the other issue I had was that the darn flange always had a little bit of wetness). It drove me crazy. That's why I switched to a powerhead feed - the flow control on the output side gave me a more steady effluent rate and a powerhead isn't capable of pressuring the vessel enough to cause any problems like that.
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!

Last edited by Delphinus; 04-20-2011 at 08:52 PM.
Reply With Quote
  #12  
Old 04-21-2011, 04:43 PM
imcosmokramer imcosmokramer is offline
Member
 
Join Date: Jan 2010
Location: cleveland
Posts: 296
imcosmokramer is on a distinguished road
Default Go

I have both. a valve limiting the pressure from the return, and one limiting the outlet. I'm sure it's overkill, but hey, isn't that what we're in this hobby for?
________

Last edited by imcosmokramer; 09-28-2011 at 08:59 PM.
Reply With Quote
  #13  
Old 04-21-2011, 06:42 PM
RuGlu6 RuGlu6 is offline
Member
 
Join Date: Sep 2008
Location: Vancouver PoMo
Posts: 829
RuGlu6 is on a distinguished road
Default

Quote:
Originally Posted by whatcaneyedo View Post
I've done the required reading for 2 part but to me it still sounds like a lot more work compared to a Ca reactor if you can figure it out.
+1
same here, reactor is way cheaper, simpler (once you figure it out, they all are the same principle), less testing and corals love it!
If dosing screwed its more trouble in very short time. If calc reactor screwed you have a lot longer to fix the problem.

Sure dosing is a nice toy, just like LED lighting (compare to MH) but it cost so much more initially as well as in the long run to replace all vulnerable parts i am staying away from it.

I go for what is simpler, has less vulnerable/breakable parts, easy to control/fix, does not require large investment and the only moving part is the circ pump. Can't make it more simple.
Reply With Quote
  #14  
Old 04-21-2011, 06:46 PM
RuGlu6 RuGlu6 is offline
Member
 
Join Date: Sep 2008
Location: Vancouver PoMo
Posts: 829
RuGlu6 is on a distinguished road
Default

Quote:
Originally Posted by Delphinus View Post
One cautionary note about T'ing off the sump return like what has been described above: the flowrate should be controlled at the inlet side of the reactor (ie., like how Mark has shown, the valve must be between the sump return pipe and the reactor ... not on the output side of the reactor). The reason for this is that sump return pumps might be capable of producing enough pressure inside the reactor that the acrylic seams and the flange are under more stress. I actually blew up a reactor doing this (weak seam I guess, I don't think that's typical, but certainly the other issue I had was that the darn flange always had a little bit of wetness). It drove me crazy. That's why I switched to a powerhead feed - the flow control on the output side gave me a more steady effluent rate and a powerhead isn't capable of pressuring the vessel enough to cause any problems like that.
This is also a very good point.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 01:19 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.