Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #11  
Old 12-07-2009, 04:05 AM
banditpowdercoat's Avatar
banditpowdercoat banditpowdercoat is offline
Member
 
Join Date: Oct 2007
Location: 100 mile hse BC
Posts: 2,568
banditpowdercoat is on a distinguished road
Default

Styrofoam WILL NOT LEVEL A TANK I can not stress that enough!!!! if the tank is low in a corner, there will me bore water in said corner, and more weigth on the styro, which will compress more, and lead to more water in corner! Styro is fro tanks with no bottom trim. where the bottom pane of glass rests directly on the stand. have a little pebble, or sawdust flake between the stand and the glass, can lead to immense point loading pressures. Styrofoam smothens out the stand irregularities like this. It WILL NOT make a tank sit level on an unlevel stand
__________________
Dan Pesonen


Umm, a tank or 5
Reply With Quote
  #12  
Old 12-07-2009, 04:27 AM
new but handy new but handy is offline
Member
 
Join Date: Dec 2008
Location: vernon b.c.
Posts: 303
new but handy is on a distinguished road
Default

Quote:
Originally Posted by Navigator View Post
Yeah, welcome to my personal hell - concrete floors are not level, contrary to logical thought since it SHOULD flow, but clearly didn't.

I am interested in the opinion about gaps though - My stand has a couple too after it's been shimmed to level and wonder if I should be jamming stuff in there or not.
concrete doesn't flow like water. How do you think we build stairs? I would keep putting shims under it untill I filled all the gaps.
Reply With Quote
  #13  
Old 12-07-2009, 05:28 AM
Navigator Navigator is offline
Junior Member
 
Join Date: Oct 2009
Location: Red Deer, Alberta
Posts: 14
Navigator is on a distinguished road
Default

Yup, I got to the concrete doesn't flow fast enough to self level conclusion after the discovery of a half inch high hump in the middle of where I wanted my tank to live.
Reply With Quote
  #14  
Old 12-08-2009, 01:25 AM
cuz's Avatar
cuz cuz is offline
Member
 
Join Date: May 2009
Location: lethbridge
Posts: 601
cuz is on a distinguished road
Default

so i guess another good question is...how does a person raise an existing tank without draining it?? would be good to know if i ever decide to level mine perfect, draining it is almost not an option!
Reply With Quote
  #15  
Old 12-08-2009, 01:39 AM
MMAX's Avatar
MMAX MMAX is offline
Member
 
Join Date: Feb 2008
Location: Innisfail, Alberta
Posts: 748
MMAX is on a distinguished road
Default

Almost impossible I'd say. Better start draining.
Reply With Quote
  #16  
Old 12-08-2009, 02:52 AM
viperfish's Avatar
viperfish viperfish is offline
Member
 
Join Date: Aug 2009
Location: Dawson Creek
Posts: 684
viperfish is on a distinguished road
Default

When I set up my 180 on my basement floor there was a difference of 3/8" over 6'. I screwed temporary bracing to the stand and levelled everything up, I then covered the outside gap (making a temporary form) and poured floor levelling compound inside the stand (I made the plywood bottom removeable for this reason). This stuff works great, it will automatically level itself and finds every crack and crevice. Once this dries you will have every inch of floor in contact with the stand and zero stress transferred to the tank. The levelling compound is available pre mixed and as a dry powder which you can mix yourself. I works on any surface, wood, concrete etc. The brand is Stone Mason, I bought mine at Home Depot. It was the first time I had ever used it, I even bought a trowel in case the auto levelling was a crock but I didn't need it. I thought about shims but with the weight of a 180, I wanted more uniform support. I built my stand with 2x6 and it is very heavy duty, but I still wanted it on a solid base for peace of mind.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 09:44 PM.