Default PLC Controller

So looking around EBay the other day i managed to pick up a PLC cheaper than most light timers. So, i bought it, and started thinking of the endless possibilities of having a PLC for my tank. It's just a small PLC(8inputs, 2analog, and 4 outputs), its expandable to more, so i'll be keeping an eye on EBay for deals. While i wait for the PLC to ship i've started writing a program for it. I have a thermocouple/tranmitter, so i have temp readings, which i can put on the display. I've seen PH monitors, but i think i might be able to find something more usefull for that second analog, possibly Salinity, or something else. So far i Have:

-Light Timer - the reason i got it
-Over Temp. Shutoffs - Heaters off, fans on, still hot and the MH lights will turn off
-Feed Cycle - Main Pump off for 15 min, and future output for a auto pellet feeder
-AutoTopoff - figured i could make a cheap float sensor/solinoid setup
-Skimmer Full - Another cheap float sensor, that just pops up on the display when the skimmer's full


I've seen that other people have PLC's in their tanks, and my biggest question would be, what is worth automating? What is usefull? There's usually a way to automate something cheaper than a night out, so what would be a good idea for something to try?
Reply With Quote
  #2  
Old 09-26-2009, 05:18 PM
tikkle tikkle is offline
Member
 
Join Date: Oct 2007
Location: Burnaby
Posts: 31
tikkle is on a distinguished road
Default

Do you have a sump?
Reply With Quote
  #3  
Old 09-26-2009, 05:58 PM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

I've got a PLC with dozens of channels and all I ended up using it for is to control my heater then a fan for evaporation. Overkill but is good though as my temperature is steady.
__________________
my tank
Reply With Quote
  #4  
Old 09-26-2009, 06:52 PM
banditpowdercoat's Avatar
banditpowdercoat banditpowdercoat is offline
Member
 
Join Date: Oct 2007
Location: 100 mile hse BC
Posts: 2,568
banditpowdercoat is on a distinguished road
Default

Sounds like you got a Siemens LOGO! I have a few of them running my tanks and ATO systems.

Skimmer full, use the float to control the skimmer air inlet. No air, no skimming, no chance of overflowing and spilling on your floor when your away or don't notice the full light.
__________________
Dan Pesonen


Umm, a tank or 5
Reply With Quote
  #5  
Old 09-26-2009, 09:00 PM
Lampshade's Avatar
Lampshade Lampshade is offline
Member
 
Join Date: Aug 2009
Location: Abbotsford
Posts: 629
Lampshade is on a distinguished road
Default

Quote:
Do you have a sump?
Yes, i have 10g sump on a 55gal tank.

And yes, it is a Siemens LOGO!, great little things, used them at work for pretty much anything, half the time they're cheaper than buying relays. I like the idea with the air shutoff on the skimmer. I'm sure princess auto would have something that will work well for that, i'll see what kind of contraption i end up with.
Reply With Quote
  #6  
Old 09-27-2009, 05:26 AM
tikkle tikkle is offline
Member
 
Join Date: Oct 2007
Location: Burnaby
Posts: 31
tikkle is on a distinguished road
Default

I am using the controller mainly for auto top-off. When I was setting my tank, my bigger concern was over filling. My setup have 3 float switches in the sump and 1 in the tank. In the sump, 1 for top-off, 1 for low level, and 1 for high level. If the top-off switch doesn't stop the fill, the high level will. If sump water is low, turn off the return pump before pump goes poof. In the tank, if your overflow is plugged up, float switch will turn off the return pump. I programmed to have 30mins delay, then the top-off pump turn on. I use aqualifter pump for top-off because I want a slow top-off and if something wrong will the pump, the worse case is no top-off. Unlike using solenoid valve, if the valve stuck open, you know what happen.....

And of course individual output should be fused. You can do so much will that little thing. Have fun with it!

Is that a AC input or DC input?

Last edited by tikkle; 09-27-2009 at 05:30 AM.
Reply With Quote
  #7  
Old 09-27-2009, 12:21 PM
banditpowdercoat's Avatar
banditpowdercoat banditpowdercoat is offline
Member
 
Join Date: Oct 2007
Location: 100 mile hse BC
Posts: 2,568
banditpowdercoat is on a distinguished road
Default

Quote:
Originally Posted by Lampshade View Post
Yes, i have 10g sump on a 55gal tank.

And yes, it is a Siemens LOGO!, great little things, used them at work for pretty much anything, half the time they're cheaper than buying relays. I like the idea with the air shutoff on the skimmer. I'm sure princess auto would have something that will work well for that, i'll see what kind of contraption i end up with.

Ya, They are great. I got a 16 input one controling my AT for 2 tanks. Soon, it will control water changes too. Then I have a Logo runingthe lighting for my tanks. I am always searching for a new version Logo though, last of the serial# 0BA6 those, you can hook th Logo TD display to. Then it will have feedback and easier visual monitoring
__________________
Dan Pesonen


Umm, a tank or 5
Reply With Quote
  #8  
Old 09-27-2009, 12:36 PM
Lampshade's Avatar
Lampshade Lampshade is offline
Member
 
Join Date: Aug 2009
Location: Abbotsford
Posts: 629
Lampshade is on a distinguished road
Default

Quote:
Originally Posted by banditpowdercoat View Post
Ya, They are great. I got a 16 input one controling my AT for 2 tanks. Soon, it will control water changes too. Then I have a Logo runingthe lighting for my tanks. I am always searching for a new version Logo though, last of the serial# 0BA6 those, you can hook th Logo TD display to. Then it will have feedback and easier visual monitoring
The new ones also have 4 analog inputs, which would be nice, i picked up a 0BA5, should work out alright, the TD display would have been nice though. The mini diplay screen is pretty customizeable on the older ones, so i'll see what i end up with on that.
I'm trying to find a way to use LOGO!soft comfort for the monitoring, and then use remote PC to be able to get info from my phone. I jsut need to find a way to have my LOGO! wirelessly transmit, so that i dont need to do house reno's hiding a cable.
Reply With Quote
  #9  
Old 09-27-2009, 01:35 PM
banditpowdercoat's Avatar
banditpowdercoat banditpowdercoat is offline
Member
 
Join Date: Oct 2007
Location: 100 mile hse BC
Posts: 2,568
banditpowdercoat is on a distinguished road
Default

Hmm, sounds inrteresting. I know about the analog inputs on the new Logo's. I use them all over the mine site here. Great little stand alone processors . Love the PT100 input modules. Direct temp measurement. Omega.com is great for sensors too.

Are you an electrician by chance, or just fooling around with them??
__________________
Dan Pesonen


Umm, a tank or 5
Reply With Quote
  #10  
Old 09-27-2009, 03:13 PM
Lampshade's Avatar
Lampshade Lampshade is offline
Member
 
Join Date: Aug 2009
Location: Abbotsford
Posts: 629
Lampshade is on a distinguished road
Default

I picked up a PT100 thermocouple with a 4-10mA transmitter, seemed cheaper than the PT100 module for the LOGO!, i'll just have to see how accurate it ends up being.
Transmitter
I took some courses with PLC's and industrial control, i used to work building custom industrial automated machinery. One day i'll have my own shop so i can play around again, but as for now, between a baby and a salt water fish tank theres not much money left for playing
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 08:08 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.