A 15 amp breaker is only rated for 80% continuous, so 1200W. You need a 20A circuit. I have a dedicated 20A for my 150g.

With the 20A circuit, you need to run 12g wire as well. I actually ran 10g to mine, but I happened to have some lying around form a previous job.