Default CRP question

I was looking at my tank last night, and it dawned on me that if the aqualift were to quit or get plugged the main tank would quickly overflow. What do others do to have a safe guard so this doesn't happen? Other than having the tank drilled.
__________________
Marty
50g reef, bubble king skimmer,20g sump,zeovit system, PM cal reactor
Reply With Quote
  #2  
Old 12-15-2008, 07:11 PM
fkshiu's Avatar
fkshiu fkshiu is offline
Member
 
Join Date: Sep 2005
Location: Vancouver, BC
Posts: 1,499
fkshiu is on a distinguished road
Default

Get a u-tube overflow like a Lifereef.
Reply With Quote
  #3  
Old 12-15-2008, 07:17 PM
dabandit dabandit is offline
Banned
 
Join Date: Apr 2008
Location: Langley (township)
Posts: 163
dabandit is on a distinguished road
Default

The chamber in my sump that my pump sits in is about 1/2 gallon,which my display can handle,you could make it even smaller if you use an auto top off. Worse case scenario I burn out a pump but I believe it has a thermal overload anyway.
Reply With Quote
  #4  
Old 12-15-2008, 07:22 PM
dabandit dabandit is offline
Banned
 
Join Date: Apr 2008
Location: Langley (township)
Posts: 163
dabandit is on a distinguished road
Default

And my sump holds enough capacity to take the water level down to the overflow just incase the pump does burn out and the flow starts again or the power goes out. 100%fool proof. You could even get a float valve for your pump so when sump water level drops the pump shuts off

Last edited by dabandit; 12-15-2008 at 07:26 PM.
Reply With Quote
  #5  
Old 12-15-2008, 07:41 PM
untamed's Avatar
untamed untamed is offline
Member
 
Join Date: Feb 2005
Location: Coquitlam
Posts: 2,248
untamed is on a distinguished road
Default

Quote:
Originally Posted by martym View Post
I was looking at my tank last night, and it dawned on me that if the aqualift were to quit or get plugged the main tank would quickly overflow. What do others do to have a safe guard so this doesn't happen? Other than having the tank drilled.
I ran a CPR overflow for many years. I don't think that what you've said is completely accurate. You should be able to shut off the aqualift pump and nothing should really change.

Now...if the aqualift remained off for days...things will eventually go bad...but nothing should happen immediately.

I didn't use an aqualift pump...I had the top of the overflow connected to the venturi of a powerhead. Even if the powerhead was off, or the venturi plugged...the system is still closed (vaccuum), so you shouldn't have an immediate failure of the siphon.
__________________
400 gal reef. Established April, 2007. 3 Sequence Dart, RM12-4 skimmer, 2 x OM4Ways, Yellow Tang, Maroon Clown (pair), Blonde Naso Tang, Vlamingi Tang, Foxface Rabbit, Unicorn Tang, 2 Pakistani Butterflies and a few coral gobies

My Tank: http://www.canreef.com/vbulletin/showthread.php?t=28436
Reply With Quote
  #6  
Old 12-15-2008, 07:51 PM
martym's Avatar
martym martym is offline
Member
 
Join Date: Sep 2003
Location: Surrey,Bc
Posts: 578
martym is on a distinguished road
Default

If I disconnect the aqualift the siphon stops. So it will over flow.Which I think is stupid.

The oceanic sump isn't that well designed, i don't think I can control the last compartment where the return pump is.
__________________
Marty
50g reef, bubble king skimmer,20g sump,zeovit system, PM cal reactor
Reply With Quote
  #7  
Old 12-15-2008, 07:52 PM
dabandit dabandit is offline
Banned
 
Join Date: Apr 2008
Location: Langley (township)
Posts: 163
dabandit is on a distinguished road
Default

I think he's talking about the overflow failing,not the pump. Can and does happen,twice for me though my tank is drilled.
Reply With Quote
  #8  
Old 12-15-2008, 07:56 PM
dabandit dabandit is offline
Banned
 
Join Date: Apr 2008
Location: Langley (township)
Posts: 163
dabandit is on a distinguished road
Default

ahh I see the problem. Step1 sell sump,step2 build a sump around your equipment. My pump out chamber holds my water level at optimum for my skimmer(no fluctuation either) and prevents my display from overflowing. Cost me 20$ for sump tank and 12$ for the acrylic baffles the silicone I had.
Reply With Quote
  #9  
Old 12-15-2008, 07:58 PM
fiorano fiorano is offline
Member
 
Join Date: Nov 2007
Location: abbotsford BC
Posts: 322
fiorano is on a distinguished road
Default

maybe you could drain your sump for a few hours and just add a last baffle right before your pump so there would be less water for it to pump into your tank if it did fail . but then you have to make sure you watch out for evaporation and such. just an idea.
Reply With Quote
  #10  
Old 12-15-2008, 07:58 PM
robert J robert J is offline
Member
 
Join Date: Jul 2008
Location: Richmond, B.C.
Posts: 48
robert J is on a distinguished road
Default

Once a month I disconnect the pump, take the pump out and put 2 hoses inside a very warm water bowl, let it run for 5 minutes as instruction say when I bought it, never have any problems and it runs like new again.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 07:37 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.