Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 09-09-2008, 11:02 PM
wil0311 wil0311 is offline
Member
 
Join Date: Jan 2006
Location: Moose Jaw, SK.
Posts: 37
wil0311 is on a distinguished road
Default Help ph probe calibration

I just bought a calcium reactor. I have packets of ph calibration solution of 7 and 10. Now I want to run the reactor at around 6.6 ph. So my question is can I calibrate my probe with 7 and 10, or do I need the 4 and 7 solutions? I would like to know if the probe is accurate when lower than 7 ph because I already calibrated it with the 7 and 10 solutions.

Thanks for your help.
Reply With Quote
  #2  
Old 09-09-2008, 11:16 PM
Tom R's Avatar
Tom R Tom R is offline
Member
 
Join Date: Dec 2003
Location: Surrey, BC
Posts: 1,117
Tom R is on a distinguished road
Default

I would calibrate it with 4.0 and 7.0 this will make more accurate at a predominate level of 6.60.

Tom R
__________________
My Tank Setup
http://www.canreef.com/ftotm/may08
Reply With Quote
  #3  
Old 09-09-2008, 11:35 PM
wil0311 wil0311 is offline
Member
 
Join Date: Jan 2006
Location: Moose Jaw, SK.
Posts: 37
wil0311 is on a distinguished road
Default

Ok thanks Tom I will order some 4.0 packets right now.
Reply With Quote
  #4  
Old 09-10-2008, 01:00 AM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

might make it more accurate but the slope is probably close enough for a reactor with 7 and 10.

Should try a little experiment with a solution of say around 6.6 or at the least cal with the 7 and 10 and tell us what the 4 comes in at.
Reply With Quote
  #5  
Old 09-10-2008, 01:22 AM
Jason McK's Avatar
Jason McK Jason McK is offline
Member
 
Join Date: Mar 2003
Location: Ladner,BC
Posts: 3,032
Jason McK is on a distinguished road
Default

Typically when using a PH probe to measure your tank PH you Calibrate at 7 and 10. If you are using the probe in a CA reactor you Calibrate and 4 and 7.
The difference is very noticable when using the probe in the reactor. I went from calibrating at 7 and 10 to 4 and 7 and my probe rose 0.4. That is a lot when it come to melting Calcium carbonate

J
__________________
My old Tank Shut down Jan 2011
New 220G build about to start
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 09:00 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.