Told you it would be easy!

Throughput you mention is about 60 gpd, so about 60% of rating if you're using a 100gpd membrane. That's actually not far off the mark. We don't get 100% of the rating through these things anyhow, but it is a function of a couple of variables. The most obvious is the household pressure. If you have a pressure regulator on your house (seems to me a lot of newer houses have this), it will dial down the capacity of the RO/DI. When I moved into my new house I noticed my RO/DI production capability went down dramatically, I found that my old house was running about 96psi, my new house around 80psi on the inlet side but only about 60psi after my pressure regulator.

I first tried opening up my regulator all the way, then found out that the reason for my house to have the regulator is that the showers have valves that are "on or off" (ie, no pressure control, just temperature control), and showers at 96psi hurt

So I dialed it back down to 60psi, and just tapped my RO/DI to before the regulator. Now that my area has grown the city has increased supply pressure back up to 96psi so I get about 80gpd out of my 100gpd unit.

Before summer comes I'm going to bypass my outside tap lines as well. 60psi isn't enough pressure to run two impulse sprinklers (the ones that go tsh-tsh-tsh-tsh-tsh!tsh!tsh!tsh!-tsh-tsh-tsh). I can get by with one but as soon as turn on two they just sit there and stop tsh-tsh'ing.

Another factor to consider is temperature, and our water comes in pretty cold. There's not much you can do about this one though. Tapping hot water into the RO/DI supply is a bad idea because although it increases water production, it causes early membrane failure. So a lot more expensive in the long run.

But you can look into things like pressure booster pumps and permeate pumps to aid in increased production if you find "you need a little more".

Anyhow welcome to RO/DI
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!
Reply With Quote
  #2  
Old 03-11-2008, 12:14 AM
ElGuappo's Avatar
ElGuappo ElGuappo is offline
Member
 
Join Date: Feb 2008
Location: Calgary, Ab
Posts: 1,593
ElGuappo is on a distinguished road
Cool

[quote=Delphinus;308606]
Before summer comes I'm going to bypass my outside tap lines as well. 60psi isn't enough pressure to run two impulse sprinklers (the ones that go tsh-tsh-tsh-tsh-tsh!tsh!tsh!tsh!-tsh-tsh-tsh). I can get by with one but as soon as turn on two they just sit there and stop tsh-tsh'ing.QUOTE]
sorry quote didnt work right for me.
this seems more like a volume issue than a pressure issue. your a probably triing to run 2, 3/4 inch hoses off 1, 1/2 copper to the hose bib. more pressure will not help very much.

sorry to be the barrer of bad news but if you want to correct this properly you will have to run a larger pipe from your water service to the hose bib. 40 psi is more than enought to run 2 sprinklers as long as you have enough volume.
__________________
72 Gallon Bowfront Reef.. Hardware:2x250w Luminex Elite HQI Reflectors (Phoenix Hexarc Bulbs), Galaxy 2x250w Electronic ballast, Euroreef 130 Skimmer, Sedra KSP 7000 Retern... Live Stock: Pair of Hawaiian Flame Wrasse, Leopard Wrasse, Pink Streaked Wrasse, Pair True Percula Clowns, Potters Angel, African Flameback Angel, Orange Fin Tomini Tang, Yellow Assessor, Tailspot Blenny, Purple Firefish..

45 G FW Asain Barb Community tank.


Last edited by ElGuappo; 03-11-2008 at 12:17 AM.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 12:11 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.