Default Noisy sump! Going insane! Help!!!

Hi everyone,

Please help any sugestion or solutions are appreciated.
I just instaled my new tank during the holidays with a durso standpipe I thought this would be extremely silent but what do I get instead is a silent and I mean SILENT top of tank wich is great but an extra toilet in the house in the stand in the sump (20 gal sump).

The sound of gargeling flushing splashing water coming in to the sump is driving me and my wife insane!!! To make it worse my aquarium is in the living room were the T.V. and family spend most of theire time in, so I can't really just close the door on it and move on to another room the living room is THE ROOM.

What do I do? Please Help... S.O.S---S.O.S
__________________
70 Gal. Diamond shape
20 Gal. Eco-System
1 250watt MH + 2 20watt NO Actinic
1 Mag Drive 12 return pump and circulation
Reply With Quote
  #2  
Old 01-06-2003, 02:46 PM
Dez's Avatar
Dez Dez is offline
Member
 
Join Date: Mar 2002
Location: Edmonton
Posts: 1,793
Dez is on a distinguished road
Default

You can have your overflow flow into a little tupperware container with drilled holes...

You can also put a peace of foam under the overflow pipe..

You can fill the section where it overflows into with bio-balls...

Hope this helps...

I use method # 3

Des
Reply With Quote
  #3  
Old 01-06-2003, 03:08 PM
AJ_77's Avatar
AJ_77 AJ_77 is offline
Member
 
Join Date: Mar 2002
Location: Calgary NW
Posts: 2,772
AJ_77 is on a distinguished road
Default

If you search reefcentral for "Durso mods" or "standpipe" or even "toilet" I think you will have a ton of reading. This seems to be a complaint that comes up regularly, and many have battled it.

Some of our own members have come up with nifty variants of this design as well. Use that very handy search function on the right!

Alan
__________________
----------------------
Alan
Reply With Quote
  #4  
Old 01-06-2003, 06:36 PM
ldzielak's Avatar
ldzielak ldzielak is offline
Member
 
Join Date: Nov 2001
Location: Campbell River, BC
Posts: 317
ldzielak is on a distinguished road
Default

Is the outlet of the line under the water level? You should get no sound if it is under the water level. I have a stockman stand pipe on my 33g QT and it's quiet without a hood.

Lee
__________________
Need more time for the tank... Break a leg!
Reply With Quote
  #5  
Old 01-06-2003, 07:19 PM
enzo54321 enzo54321 is offline
Junior Member
 
Join Date: Dec 2002
Location: Montreal, Canada
Posts: 24
enzo54321 is on a distinguished road
Default

I've tried to submerse the pipe but no luck!
__________________
70 Gal. Diamond shape
20 Gal. Eco-System
1 250watt MH + 2 20watt NO Actinic
1 Mag Drive 12 return pump and circulation
Reply With Quote
  #6  
Old 01-06-2003, 07:27 PM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

How is the water entering the sump? Is your overflow pipe coming straight down (i.e., vertical)? I've found there's not much you can do about the water crashing in that kind of case. You need to switch the overflow pipe so it can enter into the sump at some kind of angle (or at least have a section of gentle slope). This slows down the water so that it "slides" into the sump rather than "crashes" into the sump. I don't know if this makes sense based on my description. If you can maybe draw a rudimentrary diagram, or show us a picture of your sump setup right now maybe we can offer some more specific suggestions.

Don't worry, there is a solution out there.
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!
Reply With Quote
  #7  
Old 01-06-2003, 07:54 PM
Seriak's Avatar
Seriak Seriak is offline
Member
 
Join Date: Jun 2002
Location: Calgary
Posts: 954
Seriak is on a distinguished road
Default

I have the same issue. Right now I am living with the sound as it is not that important. However, in my past readings I have heard of people putting a U shaped peice of piping on the end of the outflow. In essense, you are bringing the pipe to the bottom of your sump and then accross the bottom and the up slightly but below the water level. Also, I have heard of people drilling tiny holes along the horizontal peice of pipe that lets out the air bubble slowly as opposed to the big loud bubbles.

Hope this helps. I will be trying this on my new sump when it gets built.

Chris
Reply With Quote
  #8  
Old 01-06-2003, 08:15 PM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

When I had a vertical overflow into the sump, I tried a U-tube. Tried it right at the water surface, below, all the way to the bottom then all the way back up. I personally found it made no difference, because in my case the problem was just the sheer weight of the water in a straight vertical column. I also had issues of the overflow "burping" (pressure building up then suddenly releasing). It was horrible. The only thing that solved this was having the overflow go nearly horizontal at one point, and then "slide" into the sump at a 45 degree angle. I can't beleive how much of an improvement that made.

In my case though, was a standing pipe type overflow in the main display, and the water drained downwards into the sump in a perfectly straight column. Definitely not the way to do things...



PS. Edit. Apparently I do not know the difference between "horizontal" and "vertical." Ooops. ops:
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!
Reply With Quote
  #9  
Old 01-06-2003, 08:29 PM
Seriak's Avatar
Seriak Seriak is offline
Member
 
Join Date: Jun 2002
Location: Calgary
Posts: 954
Seriak is on a distinguished road
Default

Hey,

Did that eleviate the water cycling in your overflow. (Burping) My overflow has the durso standpipe and it currently rises and lowers a few inches in the overflow column. I was told to adjust my pipe to 1-1'4 iinch from 1 inch. However my pipe goes striaght down and makes all sorts of sounds like you describe. Maybe a should just buy a 90 and a 45 with some more pipe and see what happens.

Chris
Reply With Quote
  #10  
Old 01-07-2003, 12:54 AM
rossb rossb is offline
Member
 
Join Date: Oct 2002
Location: Calgary, N.W.
Posts: 295
rossb is on a distinguished road
Default

I am not trying to open a can of worms here by using the dreaded abs reference...OK... but I have a similiar setup. My problem is I am using two rear overflows that sound like niagra falls. I have quietened them a bunch by adding foam and bio balls. My sump on the other hand is very quiet, and I expect this to be a bit of luck. I have two drains and at the bottom of each is a 90 followed by a run of pipe (1 1/2 abs) and at the other end another 90.

I was curious about the durso standpipe reference and I think it solved my noise problem in my tank...and gave me two my refugiums...

good question
__________________
take pictures, leave footprints
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 12:28 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.