Hi Tony,

you can use any dimmable ballast with 1-10V interface, this is a standard interface. ProfiLux outputs this 1-10V-signal and an on/off-signal. This signal can be used to shut off the ballast completely (disconnect from mains) at 0% brightness.
The wiring and shut-off is easier with our product "EVG-AP", the description can be found here:
http://www.ghl-kl.de/Produkte/Aquari...G-AP2_V400.pdf