![]() Cool i will get the batteries. I should have mentioned originally that these are USED they were backing up some communications equipment for the past few years. With a new battery they will be good as new, there really isnt much in these things that age other than the battery
![]() I will PM you guys when i get them together. Ken |
#2
|
|||||
|
|||||
![]() Do you have the model numbers for these? I may be interested as well.
chin
__________________
____________ If people don't die, it wouldn't make living important. And why do we fall? So we can learn to pick ourselves up. |
#3
|
||||
|
||||
![]() APC su1400net
http://www.apcc.com/resource/include..._sku=SU1400NET look at the "Batteries and Runtime" values on the spec sheet these are correct, the original spec sheet i looked at was INCORRECT it was for a rack mounted model. I think you can expect alot more time out of the UPS than listed if you are running PC lighting. Here are a couple pics of the units ![]() ![]() Thanks, Ken |
#4
|
|||||
|
|||||
![]() I need one of these...but know very little about them. Does anyone have any advice they could PM me about these?
|
#5
|
|||||
|
|||||
![]() Quote:
__________________
____________ If people don't die, it wouldn't make living important. And why do we fall? So we can learn to pick ourselves up. |
#6
|
|||||
|
|||||
![]() I am also interested in one. Let us know when they arrive and are ready.
__________________
Gerald Home:160Gal. Foxface, Yellow Tang, Blue Tang, Coral Beauty, Lawnmower Blenny, Starwberry Dottyback, Mandarin Goby, 2 Percula Clowns, Green Brittle Star, Brown Brittle Star, Chocolate Chip Star, Cleaner Shrimp Store: 33Gal. Green Brittle Star, Chocolate Chip Star, Peppermint Shrimp |
#7
|
|||||
|
|||||
![]() This is a friend of Marc...Ron's the name from Abbotsford
For sure I'll take One Contact at caus@shaw.ca |
#8
|
|||||
|
|||||
![]() Quote:
I was hoping someone with some electrical background and experience with UPS's could confirm that this is an appropriate unit for our uses. I've heard some about the different types of power delivered being hard on pumps. If you look at the apcc website, they make many, many models...most of which were designed to power computers, not pumps. |
#9
|
||||
|
||||
![]() Thats the same one I have right now (not on my tank though) its on my file server in the basement. bought it usedd as well..
__________________
Setup: 180G DT, 105G Refuge (approx. 300lbs LR, 150lbs Aragonite) Hardware: Super Reef Octopus SSS-3000, Tunze ATO, Mag 18 return, 3x MP40W, 2X Koralia 4's Wavemaker Lighting: 5ft Hamilton Belize Sun (2x250W MH, Blue LEDs) Vertex Calcium Reactor 2x Deltec Pellet Reactors |
#10
|
||||
|
||||
![]() Quote:
A continuous UPS is a better unit and if I'm not mistaken these units are continuous. In this case the power coming into the unit is run though a transformer and to the batteries then through the inverter and to whatever you are running off the UPS. There are 2 advantages to this, there is no millisecond drop when the unit switches to battery in the case of an interruption and because the batteries need very "clean" power the transformer must provide an almost perfect wave and constant voltage. You won't get any of the little dips and spikes out of a good UPS that you get from mains power, I can't see that being bad for a pump. Unless there is something I don't understand about pump motors I don't see where any damage could result. |