Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > Other > Lounge

Reply
 
Thread Tools Display Modes
  #11  
Old 03-09-2006, 07:58 AM
Static Static is offline
Member
 
Join Date: Jun 2005
Location: Victoria
Posts: 103
Static is on a distinguished road
Send a message via MSN to Static
Default

Quote:
Originally Posted by allincuddy
Well I have a 7/8 inch bulkhead on a 65 gallon tank andit says that size will do 440 gal/hr so that is amax. of 8 turn overs, should be good to go.3 tun overson afrag tank should be good?????
Thanks.

Do they make a 7/8" bulkhead? I've never seen any 7/8" pipe. I'm tempted to think you have a 1/2" bulkhead. Is it slip fit or female pipe threads? Remember the size of the bulkhead is actually determined by the pipe that slides/threads into it. And it's the hole inside the pip that's measured, not the outside diameter of the pipe.
Reply With Quote
  #12  
Old 03-09-2006, 11:54 PM
G1GY's Avatar
G1GY G1GY is offline
Member
 
Join Date: Nov 2004
Location: Calgary
Posts: 810
G1GY is on a distinguished road
Default

Quote:
Originally Posted by TheReefGeek
"Probably" is not a good term in plumging a reef. Leads to too many floods. That is why this calculator is dangerous.
In your first post in this thread you asked:
Quote:
Is it assuming there is pressure on top of the bulkhead or not?
The correct response from me should have been:
Hell no! There is no pressure on a drain bulkhead! Only the weight of any water that is on top of it.(Weight and pressure are two totaly different things.)

My reply with the word "probably" was just a nice way of saying "No pressure....... Only weight."

BTW, there's nothing wrong with this calculator IMO.
__________________
Gary


CAN'T WE ALL JUST GET A BONG!?!

´¯`·.¸¸.·´¯`·.¸ ><((((((º>´¯`·.¸¸.·´¯`·.¸ ><((((((º>
`·.¸¸.·´¯`·.¸¸.·´¯`·.¸ ><((((º> `·.¸¸.·´¯`·.¸¸.·´¯`·.¸ ><((((º>
´¯`·.¸¸.·´¯`·.¸¸.·´¯`·.¸ ><((((((º> ´¯`·.¸¸.·´¯`·.¸¸.·´¯`·.¸ ><((((((º>
Reply With Quote
  #13  
Old 03-10-2006, 05:19 AM
TheReefGeek's Avatar
TheReefGeek TheReefGeek is offline
Member
 
Join Date: Jan 2006
Location: Edmonton, Alberta
Posts: 1,503
TheReefGeek is on a distinguished road
Default

Ok, so does the calculator assume there is no weight for the flow rates it spits out then?

I am not a physics expert, sorry if I used the wrong terms.

In my basic knowledge of physics, isn't one of Newton's first laws f = m * a, or force = mass times acceleration? Force is aptly named as N, for Newtons.
And water having mass, being pulled down by gravity at 9.81? m/s squared, will create force. That force when partially blocked at a bulkhead would create pressure, pressure expressed as Newtons per square inch? Maybe there is no pressure right at the bulkhead, just the surrounding glass?

I'm not sure, I just think you can put more through a bulkhead where there is more water sitting on top of the bulkhead than if there is none?
__________________
Rory

Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 05:50 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.