Portal | PhotoPost Gallery | Register | Blogs | FAQ | Members List | Calendar | Search | Today's Posts | Mark Forums Read |
![]() |
|
Thread Tools | Display Modes |
|
#1
|
|||||
|
|||||
![]() That looks really good i really like the stand and tank. Will you be covering the overflow with black acrylic or a thin layer of tinted glass? Also i would maybe sugest changing your sump to a normal 5 gallon or make yourself a custom sump.. that little think might be hard to fit bafles and what not in to.
are you going BB? |
#2
|
||||
|
||||
![]() Quote:
As for the bottom, no, I'm going with a shallow sand bed as I already have a Pistol/Goby pair for the tank sitting at the LFS.
__________________
Mark... ![]() 290g Peninsula Display, 425g total volume. Setup Jan 2013. |
#3
|
||||
|
||||
![]() Well, after some suggestions on my choice of a sump tank, I've purchased a 5 gallon glass tank and will be using that for my sump. I've already put in two glass baffles to help reduce micro-bubbles and will try to take some pics tonight.
For some reason, the 5 gallon rectangular tank seems smaller than the Eclipse 5 gallon hex tank...
__________________
Mark... ![]() 290g Peninsula Display, 425g total volume. Setup Jan 2013. |
#4
|
||||
|
||||
![]() Well, I did some dry fitting of my Herbie plumbing today and was hoping for some input to make sure that I haven't screwed anything up.
The rear pipe would be my emergency overflow pipe. I left it high so that I will hear it if water starts needing to use this pipe. The front pipe has a gate valve for adjustment and a union so that I can take it apart if I need to. Please give me your opinion.
__________________
Mark... ![]() 290g Peninsula Display, 425g total volume. Setup Jan 2013. |
#5
|
|||||
|
|||||
![]() hey, i would suggest a true union above the gate valve and one for the back up retern to... just incase you need to move the tank or fix a problem with the gate... good call on a gate and not using 90 elbows. Will your return be run up over the back?
|
#6
|
|||||
|
|||||
![]() Quote:
I would actually have the emergency drain go all the way down into the sump water. A Herbie seems to work best when there's is just a trickle of water going down the emergency drain. As well, barometric pressure can cause the water level in the overflow to vary over the course of a day which will sometimes cause a trickle to go down the emergency drain. Having the emergency drain that high would cause a lot of unnecessary splashing and salt creep. If your main drain is clogged, the massive flushing sound from the emergency drain going full bore will be more than than enough to alert you to an issue. |
#7
|
||||
|
||||
![]() Machete, the return will be going up over the back...I have an SCWD and two u-tubes which will hopefully give me some alternating currents in the tank. I also have a union for the emergency but wasn't sure whether to use it or not. If I lower the emergency pipe into the tank as well, I will for sure need to use it.
Fkshiu, thanks for the advice...I don't have any Herbies to readily look at so all advice is appreciated. I will lower the emergency as you suggested. Anyone else with some thoughts?
__________________
Mark... ![]() 290g Peninsula Display, 425g total volume. Setup Jan 2013. |
#8
|
|||||
|
|||||
![]() The herbies I have seen, all the emergency pipes are left out of the sump water level, including my tank. If it is submerged, it will be just as quiet as the main drain if you get a clog. The whole point of a herbie is silence, having a trickle in the emergency would kind of defeat the purpose, IMO.
I'd leave it where it is... and I would scrap the union on the emergency to, The emergency pipe is usually tall enough in the overflow that it only drains the for and inch or so (again, on the herbie systems i have seen).
__________________
180G Office Reef. Started Sept 2012 http://www.canreef.com/vbulletin/showthread.php?t=88894 62G Starfire Reef. Started Jan 2013 http://www.canreef.com/vbulletin/showthread.php?t=89988 |
![]() |
Thread Tools | |
Display Modes | |
|
|