Quote:
Originally Posted by ReefJunkie View Post
OK I realized this a long time ago...kinda obvious, but I am not going to drain my tank, take it off the stand, pull the sump out, build another bigger sump.......


+1 ?? thanks for the help

My apologies, I didn't see anywhere previous in the thread where you mentioned that it was not feasible to run without the check valve due to your current sump size.
__________________
Mike
77g sumpless SW
DIY 10 watt multi-chip LED build http://www.canreef.com/vbulletin/showthread.php?t=82206
Reply With Quote
  #12  
Old 12-10-2009, 09:14 PM
ReefJunkie's Avatar
ReefJunkie ReefJunkie is offline
Member
 
Join Date: Nov 2006
Location: Sunshine Coast
Posts: 116
ReefJunkie is on a distinguished road
Default

No apologies necessary. My fault for lack of information.
You are totally right whatcaneyedo my mistakes in the start are a pain in the a$$ now and I will have to break it down and do it right, but it has to wait till after the holidays at least. For now...band aid.
__________________
Paul
Reply With Quote
  #13  
Old 12-10-2009, 09:31 PM
ReefJunkie's Avatar
ReefJunkie ReefJunkie is offline
Member
 
Join Date: Nov 2006
Location: Sunshine Coast
Posts: 116
ReefJunkie is on a distinguished road
Default

OK you guys got me thinking, maybe I could go with no check valve if I can reduce the amount of water backflow into the sump by raising my return outlets...hmmm
__________________
Paul
Reply With Quote
  #14  
Old 12-10-2009, 09:38 PM
untamed's Avatar
untamed untamed is offline
Member
 
Join Date: Feb 2005
Location: Coquitlam
Posts: 2,248
untamed is on a distinguished road
Default

Quote:
Originally Posted by ReefJunkie View Post
OK you guys got me thinking, maybe I could go with no check valve if I can reduce the amount of water backflow into the sump by raising my return outlets...hmmm
Yes...that is what you need to be thinking about to eliminate the check valve.
__________________
400 gal reef. Established April, 2007. 3 Sequence Dart, RM12-4 skimmer, 2 x OM4Ways, Yellow Tang, Maroon Clown (pair), Blonde Naso Tang, Vlamingi Tang, Foxface Rabbit, Unicorn Tang, 2 Pakistani Butterflies and a few coral gobies

My Tank: http://www.canreef.com/vbulletin/showthread.php?t=28436
Reply With Quote
  #15  
Old 12-12-2009, 02:40 AM
KrazyKuch's Avatar
KrazyKuch KrazyKuch is online now
Member
 
Join Date: Dec 2004
Location: Calgary S.W
Posts: 656
KrazyKuch is on a distinguished road
Send a message via MSN to KrazyKuch
Default

Here is the type of Check Valve I use this


I have it mounted horizontally and it works perfect........I needed one cause Having anti syphon holes on a dart with a single outlet would spray water all over the place and when I placed them lower in the water then my sump would overflow so I had to go with a check valve.
__________________
500G Mixed Reef



__________________________________
Electrician, Electronics Technician, I can help with any electrical questions you might have!!
__________________________________

Kevin
Reply With Quote
  #16  
Old 12-12-2009, 04:39 PM
ReefJunkie's Avatar
ReefJunkie ReefJunkie is offline
Member
 
Join Date: Nov 2006
Location: Sunshine Coast
Posts: 116
ReefJunkie is on a distinguished road
Default

Thanks for the info Kevin....as far as this problem goes it's on the back shelf now since I just cracked my sump!
__________________
Paul
Reply With Quote
  #17  
Old 12-13-2009, 10:06 AM
Lampshade's Avatar
Lampshade Lampshade is offline
Member
 
Join Date: Aug 2009
Location: Abbotsford
Posts: 629
Lampshade is on a distinguished road
Default

As a quick fix.. you could change out the elbow above the checkvalve for a Tee, and put an arrestor above it. if you really want a quick fix you could even just drill and fill it in. Any building supply store generally has them, they're used for basement faucets, toilets, washing machines, stuff like that. They come brass or plastic, washing machine ones are generally plastic, and only run you about $20-$30 (yeah a lot for a chuck of plastic with an air cushion behind it). Also noticed the double elbows for what looks like power cord access, this could be the main problem of the water hammer, if you take that out while fixing your sump just throw a flexi pipe for the corner and you might dodge the problem completely. Anyways, good luck with the sump
Reply With Quote
  #18  
Old 12-13-2009, 02:00 PM
Marlin65's Avatar
Marlin65 Marlin65 is offline
Member
 
Join Date: Jan 2008
Location: New Westminster
Posts: 1,024
Marlin65 is on a distinguished road
Default

Quote:
Originally Posted by KrazyKuch View Post
Here is the type of Check Valve I use this


I have it mounted horizontally and it works perfect........I needed one cause Having anti syphon holes on a dart with a single outlet would spray water all over the place and when I placed them lower in the water then my sump would overflow so I had to go with a check valve.
I use this check valve as well and mine hammers right now. It did not on my other tank though. It must be a plumbing problem I made the return higher in the tank with a flex line so it only hammers for a bit now untill the water drops.
__________________
150 Gal system 3'x3' 400W M/H, Bekett skimmer, Dart return,1/4 HP Chiller
180 Gal Drop tank, LED lights, Bubble master 250 skimmer,Hammerhead on a closed loop, Speed wave return.
Reply With Quote
  #19  
Old 12-28-2009, 03:13 AM
ZachAttack ZachAttack is offline
Member
 
Join Date: Dec 2009
Location: Fraser Valley
Posts: 50
ZachAttack is on a distinguished road
Default re

yeah, that sounds like it would work. if you drill a hole right below the waterline (the lowest point of water that can be drained without overflowing the sump) the hole will let in air cutting the siphon...
Reply With Quote
  #20  
Old 12-28-2009, 04:36 AM
Skimmerking's Avatar
Skimmerking Skimmerking is offline
acanthastrea freak
 
Join Date: Jun 2002
Location: Virden, Manitoba
Posts: 5,687
Skimmerking is on a distinguished road
Send a message via ICQ to Skimmerking Send a message via MSN to Skimmerking
Default

Quote:
Originally Posted by KrazyKuch View Post
Here is the type of Check Valve I use this


I have it mounted horizontally and it works perfect........I needed one cause Having anti syphon holes on a dart with a single outlet would spray water all over the place and when I placed them lower in the water then my sump would overflow so I had to go with a check valve.
hey man you can always use a piece of foam to allow the air to get in and still have the water get defused alot.

Quote:
Originally Posted by ZachAttack View Post
yeah, that sounds like it would work. if you drill a hole right below the waterline (the lowest point of water that can be drained without overflowing the sump) the hole will let in air cutting the siphon...
exactly and try to dril a hole on a angle if you can. and drill it on the back of the pipe so if it does spray it will hit the tank and not go out front.......
__________________
180 starfire front, LPS, millipora
Doesn't matter how much you have been reading until you take the plunge.
You don't know as much as you think.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 03:26 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.