Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 03-02-2017, 03:31 PM
smokinreefer's Avatar
smokinreefer smokinreefer is offline
Gold Member
 
Join Date: Aug 2001
Location: burnaby,bc,canada
Posts: 1,437
smokinreefer is on a distinguished road
Send a message via MSN to smokinreefer
Default

Hmmm... no horizontal runs...
I have a roughly 14' horizontal run with maybe 8" of play in height...

Is there another quiet drain set up more suitable for my situation?

And to throw a wrench into the mix, if I have an in-line frag tank inside the stand, should I just feed it from a tee off the main display overflow drain and have one more seperate overflow line, or I suppose I would need an additional 2 drain lines for the frag tank (1 drain and one back up)
__________________
- S H A O -
Reply With Quote
  #2  
Old 03-02-2017, 07:53 PM
tang daddy's Avatar
tang daddy tang daddy is offline
Likes to play with Fish
 
Join Date: Oct 2006
Location: Richmond
Posts: 1,482
tang daddy is on a distinguished road
Default

The frag tank under your display could just have some water T'off from the return pump and the drain could tie in to the emergency drain to save from adding another line to the sump.

This is quite a substantial project as the run is over 25' or more from the basement to the display. I think you will have a hard time finding a return pump that can do that and still keep a higher gph unless you have a secondary pump inline to the supply boosting it up half way on the line....make sense?
__________________
Always looking for the next best coral...

90g starphire cube/400mhRadium20k/2 XHO/2x27w UV/2x39w T5/ 3 Trulumen led strips
Reply With Quote
  #3  
Old 03-03-2017, 12:19 AM
smokinreefer's Avatar
smokinreefer smokinreefer is offline
Gold Member
 
Join Date: Aug 2001
Location: burnaby,bc,canada
Posts: 1,437
smokinreefer is on a distinguished road
Send a message via MSN to smokinreefer
Default

Gotcha on plumbing the frag tank.

I get what you mean on the secondary pump.
Hopefully I can find a good pressure rated pump.

From what I have read, the D.C. Pumps just don't perform well under pressure.
__________________
- S H A O -
Reply With Quote
  #4  
Old 03-03-2017, 08:19 PM
tang daddy's Avatar
tang daddy tang daddy is offline
Likes to play with Fish
 
Join Date: Oct 2006
Location: Richmond
Posts: 1,482
tang daddy is on a distinguished road
Default

Basically you have one pump going half way then another pump inline pumping it the rest of the way, if you run an external like a dart gold you could get away with one but....a guy on the island has gone through 2 so not sure if those are the gold standard nowadays lol.
__________________
Always looking for the next best coral...

90g starphire cube/400mhRadium20k/2 XHO/2x27w UV/2x39w T5/ 3 Trulumen led strips
Reply With Quote
  #5  
Old 03-03-2017, 08:35 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Run 1.5" for all three lines, 3/4 return is would be silly for a tank that size, would expect a plumber to know better

You can use the head loss calc on reef central to estimate total head pressure and while frictional losses are totally dependent on the pump flow rate the pump you'll probably want will end pushing close to twice as much flow through 1.5" vs 3/4".
http://www.reefcentral.com/index.php...oss-calculator

Also I don't see any issues with horizontal runs and a herbie drain. All lines should have some slope back towards the sump for drainage and the sump needs to be large enough for the back flow. Other than that, not much else to consider.
Reply With Quote
  #6  
Old 03-03-2017, 08:57 PM
smokinreefer's Avatar
smokinreefer smokinreefer is offline
Gold Member
 
Join Date: Aug 2001
Location: burnaby,bc,canada
Posts: 1,437
smokinreefer is on a distinguished road
Send a message via MSN to smokinreefer
Default

Yeah I've been reading about the reeflo and iwaki...
Guessing I'll have to go external on the return pump.

Ok, I'll run atleast 3 x 1.5" lines...

And I will probably put a check valve in near the sump to prevent too much backflow.
__________________
- S H A O -
Reply With Quote
  #7  
Old 03-04-2017, 04:00 AM
smokinreefer's Avatar
smokinreefer smokinreefer is offline
Gold Member
 
Join Date: Aug 2001
Location: burnaby,bc,canada
Posts: 1,437
smokinreefer is on a distinguished road
Send a message via MSN to smokinreefer
Default

Would it be recommended to have the return line into the tank be 1.5" as well?

Or tee it off into 2x 1" lines before it gets to the tank?
__________________
- S H A O -
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 04:05 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.