I would not assume so, but maybe. Magnetic fields decay with distance exponentially, so putting them directly beside each other (touching) might cause influence on each other. This could theoretically pull one of the motors or impellers aside causing premature wear. IF this happens, it is hard to say how much additional wear this might cause. You could perhaps start the one pump up while holding the other and see if there is any jarring in the pump you're holding. I would think any influence would cause a pull on the other pumps components that would wear them out too quickly, but that is really just a guess.


Dan
__________________
Link to my Tank Upgrade Thread
Dan Leus, Marine Biologist
20+ Years Marine Aquarium Experience
Save the Reef, Buy a Frag!
Reply With Quote
  #2  
Old 10-27-2012, 05:57 AM
The Grizz's Avatar
The Grizz The Grizz is offline
Member
 
Join Date: Oct 2009
Location: 15 min NE of Red Deer
Posts: 5,470
The Grizz will become famous soon enough
Default

I had 2 ocean runner 2500 & 2 marine land 1200 running in my sump all with in the same chamber for well over a year with zero issues, still have them but not in the sump anymore.
__________________
Feed the bear goodies, make a new friend, don't feed the bear...............

8' - 165gal Reef
DIY LED's Build
2012 Nano Contest Winner
Febuary 2013 POTM Winner
300 gal + 60 gal Complete DIY Build
Reply With Quote
  #3  
Old 10-27-2012, 07:46 PM
AGY AGY is offline
Junior Member
 
Join Date: Jan 2010
Location: St, Albert, Alberta
Posts: 7
AGY is on a distinguished road
Default

Quote:
Originally Posted by FragIt Dan View Post
I would not assume so, but maybe. Magnetic fields decay with distance exponentially, so putting them directly beside each other (touching) might cause influence on each other. This could theoretically pull one of the motors or impellers aside causing premature wear. IF this happens, it is hard to say how much additional wear this might cause. You could perhaps start the one pump up while holding the other and see if there is any jarring in the pump you're holding. I would think any influence would cause a pull on the other pumps components that would wear them out too quickly, but that is really just a guess.


Dan
Dan thanks! that is my concern as well. Depending on how, where and how close [i] pleace the pumps from each other the 2000 gets very loud. I am guessing Magnetic fields. what I did was place a filter pad between them and now the noice is gone> however just want to be sure am not going to wreck my pumps.

regards.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 12:29 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.