Quote:
Originally Posted by Aquattro View Post
I looked at your build thread, the ATO diagram by itself was overwhelming!! My head hurts trying to figure it out
I think that's a compliment?! - Thanks.

Anyway, it's really only complicated because I have two of everything and a bunch of float sensors as last resort fail safes. If you look at one piece by itself, it's the same as everyone else is doing.

I bought my solenoid from BWI. The nice thing about it is that it uses AC power, so there's no need to make any modifications.

http://www.bwiplumbing.com/products/...ohn-Guest.html

I''m pretty sure that this is a special order part as I had to wait several weeks for delivery.

If I were a betting man, I would speculate that this is the source.

http://www.autotopoff.com/solenoid/

I like the sprinkler valve idea, but I could never find a suitable 24V power source. Maybe I just didn't know where to look.

There's also the question of whether to put the valve before or after the ro/di unit. If you have a single input and a single output, then putting it between the source and the ro/di is probably the best thing to do. In my case, the output is tee'd and I wanted independent control of each line, so I installed it between the ro/di and the reservoir. I may revisit this in the future.

For what it's worth, I've had my crazy ATO fully operational on my 90G tank for some time now and it's so completely reliable that I have to consciously make an effort to check it's operation every so often. I generally never even think of this aspect of my system.
Reply With Quote
  #2  
Old 12-23-2010, 02:21 PM
Aquattro's Avatar
Aquattro Aquattro is offline
Just a guy..
 
Join Date: Aug 2001
Location: Victoria, BC
Posts: 18,053
Aquattro is a jewel in the roughAquattro is a jewel in the roughAquattro is a jewel in the roughAquattro is a jewel in the rough
Default

Quote:
Originally Posted by abcha0s View Post
I think that's a compliment?! - Thanks.
Ya, it was
__________________
Brad
Reply With Quote
  #3  
Old 12-24-2010, 04:10 AM
mike31154's Avatar
mike31154 mike31154 is offline
Member
 
Join Date: Jul 2008
Location: Vernon
Posts: 2,073
mike31154 will become famous soon enough
Default

If you're using a 24 volt DC sprinkler valve, why not use the sprinkler timer as well? It should come with the 24 VDC power adapter. Given the choice, I'd rather work with 24 VDC around water than 115 VAC. I have an underground sprinkler system for irrigation and it has a 12 zone timer to run it. Pretty sure there are some smaller timers with fewer zones available that would be cheaper. Actually gives me an idea, since the timer for my irrigation system has three independent programs - A, B, C, I could possibly use one of those for a similar fail safe on my RODI....
__________________
Mike
77g sumpless SW
DIY 10 watt multi-chip LED build http://www.canreef.com/vbulletin/showthread.php?t=82206

Last edited by mike31154; 12-24-2010 at 04:14 AM.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 06:51 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.