Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Tank Journal

Reply
 
Thread Tools Display Modes
  #1  
Old 09-30-2010, 08:41 AM
lobsterboy's Avatar
lobsterboy lobsterboy is offline
Member
 
Join Date: Dec 2008
Location: Calgary
Posts: 965
lobsterboy is on a distinguished road
Default

Quote:
Originally Posted by lastlight View Post
I'd replace the panel to be safe.
yeah Brett;s right, its probably safer to replace it.

and if you waited this long, another week or two isnt so bad.
Reply With Quote
  #2  
Old 09-30-2010, 01:51 PM
fishytime's Avatar
fishytime fishytime is offline
Member
 
Join Date: Mar 2007
Location: E-town
Posts: 5,390
fishytime will become famous soon enough
Default

that sucks Tony!.....didnt realize you were getting soooo close to getting this bad boy going.....
__________________
260g mixed reef, 105g sump, water blaster 7000 return, Bubble King SM 300 skimmer, Aqua Controller Jr, 4 radions, 3 Tunze 6055s,1 tunze 6065, 2 Vortech MP40s, Vortech MP20, Tunze ATO, GHL SA2 doser, 2 TLF reactors (1 carbon, 1 rowa). http://www.canreef.com/vbulletin/showthread.php?t=50034 . Tank Video here http://www.vimeo.com/2304609 and here http://www.vimeo.com/16591694
Reply With Quote
  #3  
Old 09-30-2010, 02:49 PM
Lance's Avatar
Lance Lance is offline
Member
 
Join Date: Feb 2008
Location: Powell River, B.C.
Posts: 3,572
Lance is on a distinguished road
Default

__________________
225g reef
Reply With Quote
  #4  
Old 09-30-2010, 03:21 PM
Rbacchiega's Avatar
Rbacchiega Rbacchiega is offline
Member
 
Join Date: Jun 2008
Location: I'm A Gypsy
Posts: 1,238
Rbacchiega is on a distinguished road
Default

oh man! that sucks so bad!.....but maybe, juuuuust maybe...all this hassle before will mean things go a tad easier in the long run. I hope. Cruddy deal there Tony.
__________________
75 gallon with 20 gallon sump in the works.
R. Bacchiega. Tattooer
I didn't smack you, I simply High Fived your face.
I've got so much glue on my pants it looks like a Friday night gone horribly wrong.
Reply With Quote
  #5  
Old 09-30-2010, 03:46 PM
michika's Avatar
michika michika is offline
Member
 
Join Date: Nov 2004
Location: YYC
Posts: 5,063
michika is on a distinguished road
Default

I'm cleaning out our basement and organizing everything fish related this weekend. What size glass do you need? I might just have a piece you can help take off my hands.
__________________
+.-.+.-.+.-.+.-.+.-.+.-.+
I glue animals to rocks
Reply With Quote
  #6  
Old 09-30-2010, 04:48 PM
fishoholic's Avatar
fishoholic fishoholic is offline
Member
 
Join Date: May 2007
Location: Edmonton
Posts: 4,137
fishoholic will become famous soon enough
Default




Sorry to hear that, that really sucks
__________________
One more fish should be ok?, right!!! - Laurie
Reply With Quote
  #7  
Old 09-30-2010, 05:36 PM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

On the bright side at least it's not a complete showstopper. While it does mean I have to stop filling for the moment, at least in the meantime I can get to work on powerhead placement, wavebox placement, and flow tuning ... as well as work on getting the electrical plugs all sort of tidied up and so on. Plenty things to work on it seems!

I can also take the opportunity to redo the overflow plumbing to account for a gravity feed for the skimmer. The only thing that I wonder about this is if I run a frag tank, as is the plan, then water entering the frag tank drains into the sump completely bypassing the skimmer. Water would have to re-enter the display tank, work its way through there and only then drain into the skimmer. So it's as if to make the display tank skimmed really effectively/efficiently, I have to make the frag tank skimmed really ineffectively/inefficiently. The flip side to this is that frag tank is only 40g and presumably only houses corals or some small fish and the display tank is going to have the heavy poopers, so maybe this is a negligible concern.

Two alternatives that I can see at this point are:

1) "T" the drain pipes from the frag tank and the main display together, and then route into the skimmer.
Pros: Both tanks get skimmed the same, cheap use of an available resource (gravity)
Cons: The skimmer has a 1" input. I have doubts that at only 5' of head pressure or thereabouts that this is enough "push" through the restriction to get enough gph through the skimmer. Also if the two drains are connected together then there is a risk that the frag tank, which sits lower than the main display, is at risk by sitting in the "flood plain" should anything cause a blockage in the skimmer, or even just a backpressure buildup, and water goes downhill and so could easily end up in the frag tank and overflow. There is an emergency overflow on the frag tank (it will be a Herbie overflow as well) but in that case it's only 1" and I think a 280g draining is too much for a 1" pipe. Hmmm I might have just convinced myself this option is a no-go.

2) Use a pump feed in the sump.
Pros: Easy and quick solution. No pipe rework. Both tanks have "equal-ish" access to the same level of skimming. No worries of one tank causing a flood in the other.
Cons: More up front cost (purchase a pump), more electrical cost

However ... "Corollary pro": The sump is already drilled for a pump. I have a Mak4 pump that has a good impeller but a shot bearing, Stircrazy has a Mak4 pump with a good bearing but a shot impeller. Perhaps the writing is on the wall here, I just have to convince myself that I'm ok with the costs and move on with things.

As for the glass, I've started looking around. So far the best option for purchase is Bow Valley. You could hear their disapproval in their voice about the size and thickness of glass, and I suppose I could take the opportunity to bump up the thickness now, but it seems to me just wasted money if I'm not replacing all 3 sides of the sump. That said, maybe I should see what it would cost to go to 8mm, leave it at that, if ever another side breaks then I bump that panel up to 8mm and so on and so on. The best part about BVA though besides being the flat-out most economical vendor, they'll do it while I wait. Everyone else I've talked to so far is all "it could take up to a week".

@Michika - thanks - if you wanted to check your basement or something, what I need is 60"x18". What's on there now is 6mm. So anything that thickness or larger. I'm kind of thinking it's a long shot you have anything like that, so no worries if you don't, but for sure, for now I'll hold off visiting BVA until I hear back from you.
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!

Last edited by Delphinus; 09-30-2010 at 05:41 PM.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 04:26 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.