![]()  | 
	
		
			
  | 
||||||||
| Portal | PhotoPost Gallery | Register | Blogs | FAQ | Members List | Calendar | Search | Today's Posts | Mark Forums Read | 
![]()  | 
	
	
| 
		 | 
	Thread Tools | Display Modes | 
| 
		 
			 
			#1  
			
			
			
			
			
		 
		
		
	 | 
||||
		
		
  | 
||||
| 
	
	
		
			
			 i set up a new aquasafe ro/di unit two days ago and the tds is still at 200ppm. is there a break in period or is it possible the ro membrane could be faulty ? 
		
	
		
		
		
		
		
	
		
		
	
	
	 | 
| 
		 
			 
			#2  
			
			
			
			
			
		 
		
		
	 | 
||||
		
		
  | 
||||
| 
	
	
		
			
			 Can you post pics. What is TDS of the water going in to unit? 
		
	
		
		
		
		
		
	
		
		
	
	
	 | 
| 
		 
			 
			#3  
			
			
			
			
			
		 
		
		
	 | 
||||
		
		
  | 
||||
| 
	
	
		
			
			 i cant post pics right now.  the tds going in is +/_ 200 ppm.  i triple checked the hook ups from the instructions so i think im good there. 
		
	
		
		
		
		
		
	
		
		
	
	
	 | 
| 
		 
			 
			#4  
			
			
			
			
			
		 
		
		
	 | 
||||
		
		
  | 
||||
| 
	
	
		
			
			 I have the aquasafe ro/di unit. My well water is at about 420 ppm, unit strips to about 10 ppm. Do you have the auto shut-off and flush valve?  
		
	
		
		
		
		
		
		
			You might have a faulty membrane. Mine was working right off the start. When I was on town water at approx. 185 ppm unit stripped to about 2ppm. Last edited by ABreefkpr; 03-07-2010 at 12:20 AM.  | 
| 
		 
			 
			#6  
			
			
			
			
			
		 
		
		
	 | 
|||||
		
		
  | 
|||||
| 
	
	
		
			
			 I would suspect membrane. It should be bringing the TDS down to <10 within a couple minutes. That said, how long are you waiting? At startup there is typically a "TDS surge" which can last anywhere from 5-10 minutes. Usually what I do is flush the membrane for a good 5 minutes and then check the TDS. If it's still 200ish after 5-10 minutes though, then the membrane is toast. 
		
	
		
		
		
		
			
				__________________ 
		
		
		
		
	
		
		
	
	
	-- Tony My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!  | 
| 
		 
			 
			#8  
			
			
			
			
			
		 
		
		
	 | 
||||
		
		
  | 
||||
| 
	
	
		
			
			 i do have the flush valve. the instructions said to adjust to 3:1 discharge to good water.  it must be the membrane shot. i will phone them on monday to see whats up.  thanks alot. 
		
	
		
		
		
		
		
	
		
		
	
	
	 | 
![]()  | 
	
	
| Tags | 
| aquasafe, high tds, ro trouble, ro/di | 
| Thread Tools | |
| Display Modes | |
		
  | 
	
		
  |