Old 02-18-2008, 06:32 AM
untamed's Avatar
untamed untamed is offline
Member
 
Join Date: Feb 2005
Location: Coquitlam
Posts: 2,248
untamed is on a distinguished road
Default

Quote:
Originally Posted by Kabong View Post
I got it.
So Technically it would probably work, But I'd just be begging for a flood without a back up pipe.

Any one else running a Herbie setup could you give your drain size + your Aprox flow.
Yes, you can silence a single overflow pipe using a gate valve and run a Herbie using only 1 pipe. But it would be stupid.

My system uses twin Herbies (4 actual drains). Each is 1.5". Flow of about 800-1000 gph through each side.

Here's an idea that might work. Add a second overflow pipe that comes up from your primary overflow pipe that will flow if the overflow box level goes too high. In the picture below, the red dot is your gate valve. You would need to get the height of this emergency drain just right.

Call this the "Untamed" mod.
__________________
400 gal reef. Established April, 2007. 3 Sequence Dart, RM12-4 skimmer, 2 x OM4Ways, Yellow Tang, Maroon Clown (pair), Blonde Naso Tang, Vlamingi Tang, Foxface Rabbit, Unicorn Tang, 2 Pakistani Butterflies and a few coral gobies

My Tank: http://www.canreef.com/vbulletin/showthread.php?t=28436

Last edited by untamed; 02-18-2008 at 06:35 AM.
Reply With Quote
 

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 10:05 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.