![]() Probe starts
175W = ANSI M57 250W = ANSI M58 400W = ANSI M59 Pulse starts 175W = ANSI M137 250W = ANSI M138 400W = ANSI M135 150W HQI = ANSI M81 250W HQI = ANSI M80 As far as matching ballasts (probe vs. pulse) to lamps, best thing to do is try to decide on a lamp you want to use, then look up what ballast is best for it. This information may be harder to find but usually manufacturers and vendors post some data. And while it's best to match a ballast to a lamp, it may not be a hard and fast rule. I use Ushio's over one tank, 175W, according to Ushio I should be using M137. But I use M57 because that's what I have. The lamps work. They may not start as nice as they could and they may not be as bright as they could be, but they're nice and they work and things look good under them. So if you can get these ballasts for cheap or for free, it's probably worth it, as long as you're OK doing your own wiring for them (it's not that hard). Advance, one of the larger maker of ballasts, has a lot of info on their website. You can go to the HID ballast lookup section directly with this link: http://www.advancetransformer.com/ec...hid_lookup.asp ... Or by going to the front page ( www.advancetransformer.com ), then selecting "Catalog -> HID Lookup". Hope this helps..
__________________
-- Tony My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee! |