Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 10-27-2017, 08:37 PM
iceman86 iceman86 is offline
Member
 
Join Date: Mar 2012
Location: edmonton
Posts: 246
iceman86 is on a distinguished road
Default

Quote:
Originally Posted by Delphinus View Post
What kind of reactor media are you using? Do you have a CO2 recirc line?

I'm fairly certain it's a CO2 buildup. The reactor I use right now doesn't have a recirc line and it's prone to this issue as well (I'm tempted to retro one in at some point "when I have some free time" giggle giggle! ... <sigh> but I digress).

Even reactors I've had with a recirc line were eventually prone to this issue. Especially with the older style finer-grained ARM media it would eventually soften enough that the flow through the media would be too resistive and the CO2 would build up. That was always the cue for me to replace my media and it was one of the reasons I actually stopped using a reactor at all for a few years and went to 2-part dosing. The only thing is I don't really like 2 part dosing, the results of coral growth are just better overall with a reactor, at least for me. So here I am back to CO2 and reactors. But yeah, the unit I have right now always has a huge bubble at the top. I was sort of hoping that coarser media was less prone to this but I bet in enough time it will happen with it as well (especially without a recirc line).
This i the same reactor i use http://premiumaquatics.com/themes/pa...RFCa4600px.jpg

It does have the recirculating line at the top and brings the water to the pump and pushes it back out at the bottom of the reactor. When the air bubbles go to the top, and then get forced down into the pump, you can hear them.The effluent line sits a little lower on the lid than the recirculating line so that allows the air to keep recirculating in the reactor.

The media i use is A.R.M. extra course and it still pretty new. the rocks haven't shrunk too much and i can also see the little bubbles passing through the rocks.
Reply With Quote
  #2  
Old 10-27-2017, 09:25 PM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

What I mean by recirc line is a secondary line, usually 1/4", that can bring the gas bubble into the pump intake. The pipe that carries most of the water is likely inset into the lid a little bit thus giving the gas bubble a place to form. The recirc line would have to be flush to the inside of the lid, or even recessed a little so that it's drawing from the absolute highest point in the reaction chamber thus mitigating the size of the bubble buildup.

I'm probably not explaining this well enough. I'll see if I can dig up some photos or diagrams.
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!
Reply With Quote
  #3  
Old 10-28-2017, 04:45 AM
iceman86 iceman86 is offline
Member
 
Join Date: Mar 2012
Location: edmonton
Posts: 246
iceman86 is on a distinguished road
Default

Quote:
Originally Posted by Delphinus View Post
What I mean by recirc line is a secondary line, usually 1/4", that can bring the gas bubble into the pump intake. The pipe that carries most of the water is likely inset into the lid a little bit thus giving the gas bubble a place to form. The recirc line would have to be flush to the inside of the lid, or even recessed a little so that it's drawing from the absolute highest point in the reaction chamber thus mitigating the size of the bubble buildup.

I'm probably not explaining this well enough. I'll see if I can dig up some photos or diagrams.
I think I know what your trying to explain. The outside of the lid is flat but the inside is actually cone shaped so that the recirculating line is at the absolute highest point, thus not allowing any bubbles to form at the top and pushing them down into the recirculating pump. The effluent line sits at the lowest part of the cone lid.
Reply With Quote
  #4  
Old 10-28-2017, 04:55 PM
straightrazorguy straightrazorguy is offline
Member
 
Join Date: Dec 2012
Location: New Westminster, BC
Posts: 321
straightrazorguy is on a distinguished road
Send a message via Skype™ to straightrazorguy
Default

I have the same problem with my Vertex calcium reactor. It started while I was on vacation, after using the reactor with no problems for over 6 months. Since then I tried everything; burping the gas recirc line, messing with the pump, etc. I even contacted the Vertex people and they didn't have a good explanation or suggestion. So, I'll be watching this thread with great interest....
Reply With Quote
  #5  
Old 11-01-2017, 04:00 AM
iceman86 iceman86 is offline
Member
 
Join Date: Mar 2012
Location: edmonton
Posts: 246
iceman86 is on a distinguished road
Default

It's been a few days since I've replaced my uniseal and I also put silicone around the uniseal and the pipe going into it. I checked the reactor and there wasn't a single air bubble in it!!

Thanks everyone for your help
Reply With Quote
  #6  
Old 11-16-2017, 01:39 AM
Cujo#31's Avatar
Cujo#31 Cujo#31 is offline
Proofed by Wheelman
 
Join Date: Aug 2013
Location: Chilliwack
Posts: 204
Cujo#31 is on a distinguished road
Default

I have always "burped" my reactor every 2 or 3 days as part of my ritual. I check it more often now for leaks around the seal, but now that the reactor sits in my sump it's not such a concern any more.lmao
__________________
Cheers
Gary
604-319-0317

Last edited by Cujo#31; 11-16-2017 at 01:42 AM.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 12:31 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.