Portal | PhotoPost Gallery | Register | Blogs | FAQ | Members List | Calendar | Search | Today's Posts | Mark Forums Read |
|
Thread Tools | Display Modes |
#1
|
||||
|
||||
Maxspect Razor r420r
Hello i purchased a maxspect razor r420r and the blue channel doesnt seem to be working. Does anybody else run this light ? Have you had any problems ?
|
#2
|
|||||
|
|||||
No problems with the light what so ever. I have a pair of them for over a year. before that I had their first generation light and they offered me a credit when it ran into problems after 3 years of use.
Take it back to where you purchased it or contact Maxspect directly. |
#3
|
||||
|
||||
I have contacted maxspect directly, the problem is is that the loght is bought 2nd hand. I submitted a ticked for support but havent recieved an answer quite yet. Ive read a few problems of people running into this and was wondering if anyone on here has had this problem and got it resolved or fixed it themselves.
|
#4
|
|||||
|
|||||
I had the same happen to me on a fixture...
The pads are wired so if one goes out, they all go out... If I recall this happens when blue channel is run at 100% It was out of warranty but support gave me instructions on how to diagnose this issue. Once confirmed, I ordered a replacement pad from my LFS, and switched out the burnt pad quite painlessly.
__________________
- S H A O - |
#5
|
|||||
|
|||||
I have a razor and bought a second used one but once I took it home i realized nearly 1/4th of the LEDs are burnt out. How much were the new LED pads?
|
#6
|
|||||
|
|||||
The LED pad is about $60.
I'll post up the instructions later on how to test which pad is the one with the burnt out LED.
__________________
- S H A O - |
#7
|
||||
|
||||
That would be greatly appreciated
|
#8
|
|||||
|
|||||
To identify which LED pad is the problem:
The pads are in series, so when one is done, they will all stop working. Try bypassing a pad by shorting it. Use a copper wire and connect B+ to B-. When you bypass the faulty pad, the others will light. When you remove the cover, you will see the connections are labeled. So just follow the steps above. I used this method to isolate and replace a faulty pad. I'm a cable guy, so I just used a small piece of copper core from a piece of coax
__________________
- S H A O - |
#9
|
||||
|
||||
I had my blue channel die on both of my units after around 2 years. Maxspect did replace the control board I think. My LEDs looked burnt almost, the area around each of the blue diodes was cracked. Didnt end up replacing the light pod and they have worked for the last 6 months like new.
|
#10
|
||||
|
||||
I am an electrician aswell so shouldnt be a big deal just never dealt with lights like this. Are all the terminals labeled a(+)(-) and b (+)(-)? I havent quite opened up the fixture itself yet as i wanted to contact maxspect and see what they said.
|