HQI ballasts a bit of a misnomer. The term "HQI" only seems to exist in the aquarium industry. I believe it actually came from the bulb mfg themselves, "Halide Quartz Iodide", something like that anyways.

Ballast mfg don't list such a thing. They market ballasts based on the ANSI specs as mentioned below..

Metal Halide

M130 - 35/39 watt MH
M110 - 50 watt MH (standard and pulse start)
M85 - 70 watt MH (double-ended and BiPin lamps)
M98 - 70 watt MH (standard, pulse start, and operates some double - ended and BiPin lamps)
M139 - 70 watt MH (ceramic metal halide, some double - ended, and some BiPin lamps)
M90 - 100 watt MH (standard, pulse start, and operates some double - ended lamps)
M91 - 100 watt MH (double-ended and BiPin lamps)
M140 - 100 watt MH (ceramic metal halide, some double - ended, and some BiPin lamps)
M81 - 150 watt MH (double - ended and BiPin lamps)
M102 - 150 watt MH (standard, pulse start, and operates some double - ended and BiPin lamps)
M142 - 150 watt MH (ceramic metal halide, some double - ended, and some BiPin lamps)
M107 - 150 watt MH (energy saving probe start / Replaces 175 watt probe start lamps)
M137 - 175 watt MH (pulse start and some European lamps*)
M57 - 175 watt MH (standard probe start and some high pressure sodium lamps*)
M58 - 250 watt MH (standard probe start and some high pressure sodium lamps*)
M80 - 250 watt MH (double-ended and some European lamps*)
M138 - 250 watt MH (pulse start and some European bulbs*)
M59 - 400 watt MH (standard probe start and some high pressure sodium lamps*)
M135 - 400 watt MH (pulse start and some European lamps*)
M128 - 400 watt MH (pulse start lamps)
M47 - 1000 watt MH (standard probe start and some high pressure sodium lamps*)
M141 - 1000 watt MH (pulse start, double ended, and operates some European lamps)
M48 - 1500 watt MH (probe start lamps)
M133 - 1500 watt MH (pulse start, double-ended and some European lamps)
M134 - 2000 watt MH (pulse start - double-ended lamps)
__________________
-=Bryan=-
Reply With Quote
 

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 05:21 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.