Canreef Aquatics  

Go Back   Canreef Aquatics > News

Change Themes
Old 02-23-2013, 08:37 PM  
3669
Aqua-Digital Aqua-Digital is offline
Member
 
Join Date: Jul 2007
Location: Ottawa
Posts: 3,272
Talking NEW Tank Build !!!

I am pleased to announce the new tank build can now finally start. Thanks to Dave at Concepts for the amazing tank and stand, both are the best quality I have ever seen! The tank having a one piece Euro Brace and 100% star fire with unique total clear silicon.

The tank is 36x32x24 with external overflow. The sump will be in the basement about 8 feet below the tank.

The system will run everything we distribute one way or another but also form the basis for all future marketing photos for GHL equipment, for example the Mitras. The tank will run just one single silver Mitras HV.

Here are some photos I took at 1.45am this morning after getting off a plane back from Turks and Caicos getting in the door at 1.30am!! Something was bugging me! Did I measure our door gap right? will the stand fit? 30 minutes in the garage with a jenny bar and a tape measure confirmed my thoughts. Yep I measure wrong the stand wont fit, so it has to go through the patio doors, so now I have to snow blow the side of the house and around the swimming pool and get some lads over to get the stand through the rear patio doors. But before that the stand is off to a local cabinet makers to have a little mod done to it I did not get done during manufacture.

This will be a painstaking slow build, so next update will be a while





 


Extras
New Article
New Reply

Aqua Digital
« Previous | Next »
You Rated this Thread:

Old 03-12-2013, 10:54 PM
lastlight lastlight is offline
Gold Member
you don't need dursos really. the full siphon can just be thru bulkhead. i tune the flow so it just barely trickles into the secondary standpipe. You make the standpipe / emergency drain taller to raise the water level in the overflow box and make it as quiet as possible.
Edit
Old 03-12-2013, 10:56 PM
Aqua-Digital Aqua-Digital is offline
Member
so the emergency also allows you to balance the height of the water in the tank?
Edit
Old 03-12-2013, 10:58 PM
lastlight lastlight is offline
Gold Member
the height of water in the overflow box. the standpipe/emergency should still be a bit lower than the overflow weir / cutout so you don't raise the display's levels.
Edit
Old 03-12-2013, 11:02 PM
Aqua-Digital Aqua-Digital is offline
Member
my cut outs give too much gap between euro brace and water height thats why I asked, instead of closing off the depth of the teeth I thought it would be easier just to raise the standpipe?

I need to raise the tank level basically
Edit
Old 03-12-2013, 11:08 PM
lastlight lastlight is offline
Gold Member
i guess you could but would that scenario skim the surface as well? i'd personally silicone a strip of glass inside the overflow to raise it up a little. it could be glued behind the existing teeth.
Edit
Old 03-12-2013, 11:10 PM
Aqua-Digital Aqua-Digital is offline
Member
argh yes you are right, time to get the silicon gun out

Brilliant help thanks.
Edit
Old 03-13-2013, 01:30 AM
Aqua-Digital Aqua-Digital is offline
Member
How much gap you guys leave from water height to Euro Brace? I dont like seeing much of a gap but also need room for turbulence.
Edit
Old 03-13-2013, 03:21 AM
Skimmerking Skimmerking is offline
acanthastrea freak
Quote:
Originally Posted by Aqua-Digital View Post
How much gap you guys leave from water height to Euro Brace? I dont like seeing much of a gap but also need room for turbulence.
1.5"
Edit
Old 03-13-2013, 03:58 AM
denny_CC denny_CC is offline
Banned
there should be no need to make adjustments , heres how it works


your primary drain is your workhorse , this is going to be a full syphon. basically open your gatevalve all the way and then slowly close it untill water level is rising not falling. once the water height is about 2" above your standpipe fine tune the gatevalve closed so it matches your return, now you have a bubble free super quiet drain,fine tuning may take a little bit.

the height of the primary standpipe sets the water level in the box , shoot for about 1/2-1/3 of the overflow box so there no noise of rushing water.

no durso is needed imo and its easier to fine tune the water level looking directly at the top of the standppe, we designed your tank in a way that no fish or snails are getting in unless they are under 1/4" in size.

the water in the box wont have a lot of flow as its all syphon and it collects ditrius so be sure to clean in reguarily.

for the emergency set it at water height , i like to keep this dry untill emergencies arise, never restrict your emergency or use it for more than a trickle.

the weir is 1 1/2" deep from the eurobrace this allows for a 1" water line in the tank.


be sure to test it before walking away , test the emergency and i use marks to fine tune my primary, if after a few hours it goes down slightly ill just barely tune it....after a while the sweet spot is found.


cheers


denny
concept aquatics
Edit
Old 03-13-2013, 04:07 AM
lastlight lastlight is offline
Gold Member
Denny he wants to raise the level in the display...
Edit

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

Smilies are On
[IMG] code is On
HTML code is Off

Portal > News
All times are GMT. The time now is 03:51 PM.


Portal By vbPortal Version 3.7.1
Copyright ©2000 - 2025, phpPortals. All Rights Reserved.