I had all my ballasts burn out a week ago and thought I was done having problems.
Then whaaaat, my reactor blew up
The only thing I can think of is the solinoid stuck and the co2 built up and pop!
Attached Images
File Type: jpg B1D54EA8-1193-4F30-84A4-FDEE46E7DCA3.jpg (41.1 KB, 103 views)
File Type: jpg D64A840B-187B-4029-80CB-D2FCE392375D.jpg (23.0 KB, 84 views)
Reply With Quote
  #2  
Old 11-28-2017, 01:58 AM
Tigweldpro's Avatar
Tigweldpro Tigweldpro is offline
Member
 
Join Date: Mar 2017
Location: Calgary
Posts: 121
Tigweldpro is on a distinguished road
Default

Thats intense! Its a fair size vessel could have caused some serious damage
Reply With Quote
  #3  
Old 11-28-2017, 03:27 PM
Scythanith's Avatar
Scythanith Scythanith is offline
Member
 
Join Date: May 2008
Location: Saskatchewan
Posts: 1,088
Scythanith is on a distinguished road
Default

Yowza!
Reply With Quote
  #4  
Old 11-28-2017, 04:42 PM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

Wow, sorry to hear.

Question: How are you controlling flow into and out of the reactor?

I popped a reactor once by trying to feed it via a T'd line off my sump return. I was having issues with the flow being inconsistent so I was trying it with the needle valve on the input side of the reactor and on the outlet size of the reactor. I found with the needle valve on the input side I was still having inconsistent flow so I moved it to the output. A day later I found the whole thing split open with a huge mess on the floor.

Lesson learned! Between the CO2 regulator's pressure setting and sump return pump, it can lead to enough internal pressure to stress the seams. I prefer to have the output of the reactor as free-flow, with the flow adjustments made as the water goes into the reactor.

Anyhow hopefully you can get everything sorted out.
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!
Reply With Quote
  #5  
Old 11-28-2017, 11:40 PM
Ya Dude Ya Dude is offline
Member
 
Join Date: Oct 2007
Location: abby
Posts: 141
Ya Dude is on a distinguished road
Thumbs up

I do have the input T'd off sump pump with needle valve. The needle valve was adjusted with the out put fully open with barely any effluent pressure.
I can tell the reactor over reacted because of the silty water left behind which would explain excessive co2
I ll start by ordering a new probe and fix the reactor I guess.
Luckily I have a kalk dripper
Reply With Quote
  #6  
Old 11-29-2017, 03:22 PM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

I tried once using a 60ml/min peristaltic pump to feed the reactor. Thought I had the feed problem licked once and for all until I learned that those pumps apparently don't last more than a couple months when being used for more than a couple minutes per day to dose something. Can't win!!
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 10:09 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.