Quote:
Originally Posted by The Grizz View Post
Intake is a 2" line & returns are 1" so when running its a even ratio of 2 - 2. The pump is a Dolphin 3600 GPH.
Thanks, what do you mean ratio of 2-2?
Reply With Quote
  #22  
Old 02-24-2012, 03:41 AM
The Grizz's Avatar
The Grizz The Grizz is offline
Member
 
Join Date: Oct 2009
Location: 15 min NE of Red Deer
Posts: 5,470
The Grizz will become famous soon enough
Default

Quote:
Originally Posted by sphelps View Post
Thanks, what do you mean ratio of 2-2?
2" intake / 2 - 1" returns
__________________
Feed the bear goodies, make a new friend, don't feed the bear...............

8' - 165gal Reef
DIY LED's Build
2012 Nano Contest Winner
Febuary 2013 POTM Winner
300 gal + 60 gal Complete DIY Build
Reply With Quote
  #23  
Old 02-24-2012, 03:48 AM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Oh OK so actually you have a 2-1 ratio relating to area (2^2 : 2x1^2)
Reply With Quote
  #24  
Old 02-24-2012, 03:54 AM
The Grizz's Avatar
The Grizz The Grizz is offline
Member
 
Join Date: Oct 2009
Location: 15 min NE of Red Deer
Posts: 5,470
The Grizz will become famous soon enough
Default

Actually now that I think of it, it's really a 1-1 ratio related to water volume in & out. I might be totally off here because of an 19 hr day yesterday.
__________________
Feed the bear goodies, make a new friend, don't feed the bear...............

8' - 165gal Reef
DIY LED's Build
2012 Nano Contest Winner
Febuary 2013 POTM Winner
300 gal + 60 gal Complete DIY Build
Reply With Quote
  #25  
Old 02-24-2012, 04:01 AM
randy123 randy123 is offline
Member
 
Join Date: Nov 2009
Location: Lloydminster, AB
Posts: 75
randy123 is on a distinguished road
Default

Yeah, the OM will be over the sump, kind of like that
Reply With Quote
  #26  
Old 02-24-2012, 05:22 AM
randy123 randy123 is offline
Member
 
Join Date: Nov 2009
Location: Lloydminster, AB
Posts: 75
randy123 is on a distinguished road
Default

Grizz, what was the reasoning behind leaving the closed loop down for the first bit after starting up your tank?
Reply With Quote
  #27  
Old 02-24-2012, 07:41 AM
FragIt Dan's Avatar
FragIt Dan FragIt Dan is offline
Member
 
Join Date: Feb 2012
Location: Nanaimo, BC
Posts: 337
FragIt Dan is on a distinguished road
Default

Quote:
Originally Posted by The Grizz View Post
Actually now that I think of it, it's really a 1-1 ratio related to water volume in & out. I might be totally off here because of an 19 hr day yesterday.
Flow is relative to cross sectional area, so for 2" pipe it is 3.14x1^2= 3.14 vs 1" at 3.14x0.5^2=0.79, but two of them so 1.58. That puts it at 2:1. You would need four 1" return lines to prevent a bottle neck.
__________________
Link to my Tank Upgrade Thread
Dan Leus, Marine Biologist
20+ Years Marine Aquarium Experience
Save the Reef, Buy a Frag!

Last edited by FragIt Dan; 02-24-2012 at 07:50 AM.
Reply With Quote
  #28  
Old 02-24-2012, 02:03 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Quote:
Originally Posted by FragIt Dan View Post
Flow is relative to cross sectional area, so for 2" pipe it is 3.14x1^2= 3.14 vs 1" at 3.14x0.5^2=0.79, but two of them so 1.58. That puts it at 2:1. You would need four 1" return lines to prevent a bottle neck.
Velocity is relative to cross sectional area, in theory flow is the same no matter what but friction losses are greater with higher velocities but there are limits or critical velocities, eg pushing 200GPH though a 6" pipe won't make much difference over a 1/2" pipe. You can also drop the pi/4 when comparing ratios as it's a constant (just square diameters).

Also consider the pump Grizz uses is 1.5" in and out, the intake is one size up which is a good idea considering it's pretty restrictive. The output stays at 1.5" and then splits into two 1" lines at the OM, so at the output side it's pretty much 1-1. So to say there is a bottle neck isn't really correct, if that were true any pump that had a larger suction would have such design flaw.

That said it's still pretty restrictive plumbing which, like I said earlier, is typical with closed loops, especially with smaller tanks also containing a sump below. To say 3600GPH is going through it isn't very accurate, in the mid 2000s is probably more accurate. That combined with the return and flow probably sits pretty close to 20X. Would his LPS suffer if he dropped his turnover to 10X? Not likely.

Last edited by sphelps; 02-24-2012 at 02:07 PM.
Reply With Quote
  #29  
Old 02-24-2012, 03:23 PM
The Grizz's Avatar
The Grizz The Grizz is offline
Member
 
Join Date: Oct 2009
Location: 15 min NE of Red Deer
Posts: 5,470
The Grizz will become famous soon enough
Default

Quote:
Originally Posted by randy123 View Post
Grizz, what was the reasoning behind leaving the closed loop down for the first bit after starting up your tank?
It was blowing my sand all over the place because I didnt have my Loc-line in yet and it gave the sand time to settle a bit.
__________________
Feed the bear goodies, make a new friend, don't feed the bear...............

8' - 165gal Reef
DIY LED's Build
2012 Nano Contest Winner
Febuary 2013 POTM Winner
300 gal + 60 gal Complete DIY Build
Reply With Quote
  #30  
Old 02-24-2012, 07:22 PM
randy123 randy123 is offline
Member
 
Join Date: Nov 2009
Location: Lloydminster, AB
Posts: 75
randy123 is on a distinguished road
Default

Oh, Okay. Makes sense.

Well I think I've got it figured out...everything is ordered up. Thanks for the advice everyone.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 06:15 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.