Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > DIY

Reply
 
Thread Tools Display Modes
  #1  
Old 01-09-2012, 02:11 AM
rstar's Avatar
rstar rstar is offline
Member
 
Join Date: Aug 2008
Location: Rosetown, SK
Posts: 275
rstar is on a distinguished road
Default For all you tank building engineering types....

Picked up a 50gal tank used to upgrade from my 40 breeder. New tank dimensions are 36L X 18W X 18H and is made out of 9mm glass, tank is rimless trimless (no bracing whatsoever). My questions is: Is 9mm glass thick enough to run said tank rimless? I realy like the look of it, and would like to keep it this way. I just resealed the tank and test filled it. So far so good.
__________________
"120 Gallon - Fastest Build in the West"
20Gal Sump, 2x 250 PFO Metal Hallides running 2 20k XM Bulbs, 2X54 HOT5 1 KZ Coral Light 1 Fiji Purple, Euroreef RS 100 Skimmer, Quiet One 6000 Return Pump, 2X Tunze 6025, Nano Wavebox
~To Live Is To Reef~
Reply With Quote
  #2  
Old 01-09-2012, 02:36 AM
syncro syncro is offline
Member
 
Join Date: May 2011
Location: Calgary
Posts: 231
syncro is on a distinguished road
Default

Search the web for tank design and "safety factor". I think for most tanks you want a 2 - 3 safety factor but for rimless I've read 7 - 9. This is from memory though.
Reply With Quote
  #3  
Old 01-09-2012, 02:40 AM
Nano's Avatar
Nano Nano is offline
Member
 
Join Date: Nov 2011
Location: Wetaskiwin Alberta
Posts: 2,330
Nano is on a distinguished road
Default

I love the look of rimless as well, but am afraid of the "what if" factor, like if some one or something bumped it just right you know?? cause I'd love to go rimless, but like said I'm a bit put off by the thought of something going wrong lol
__________________
I'm not 'fallow' you must be talking about my tank!
Reply With Quote
  #4  
Old 01-09-2012, 02:50 AM
rstar's Avatar
rstar rstar is offline
Member
 
Join Date: Aug 2008
Location: Rosetown, SK
Posts: 275
rstar is on a distinguished road
Default

Exactly my problem, I am just looking for someone with the know how to put my mind at ease. 9mm is quite thick for 50G as far as I am aware, most 50s are built outof 6mm glass.
__________________
"120 Gallon - Fastest Build in the West"
20Gal Sump, 2x 250 PFO Metal Hallides running 2 20k XM Bulbs, 2X54 HOT5 1 KZ Coral Light 1 Fiji Purple, Euroreef RS 100 Skimmer, Quiet One 6000 Return Pump, 2X Tunze 6025, Nano Wavebox
~To Live Is To Reef~
Reply With Quote
  #5  
Old 01-09-2012, 03:08 AM
jostafew's Avatar
jostafew jostafew is offline
Member
 
Join Date: Apr 2010
Location: Abbotsford, BC
Posts: 185
jostafew is on a distinguished road
Default

According to this calculator you have a safety factor of around 5
http://www.theaquatools.com/building-your-aquarium

For comparison my professionally built custom rimless is 30x24x24 and has 1/2" glass (12mm) which comes in at a safety factor of 5-6. I think you're fine at that thickness.
Reply With Quote
  #6  
Old 01-09-2012, 04:14 AM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Sounds fine to me but I would assume the glass is 10mm and not 9. A good test would be to measure the max deflection of the glass when the tank is full (how much the tank bows) as that's the major design criteria for rimless tanks.

For reference my tank is 54" long and 20" tall and uses 12mm straphire.
Reply With Quote
  #7  
Old 01-09-2012, 06:57 AM
ScubaSteve ScubaSteve is offline
Member
 
Join Date: Nov 2009
Location: Vancouver
Posts: 1,591
ScubaSteve is on a distinguished road
Default

The aquatools calculator assumes rimless though they don't state it, so a safety factor of 5 should be fine. 7 to 9 is overkill. I use 10 mm glass on my rimless 24x24x20 tank. My friend has a rimless that is about 31.5x14x18 and it uses 6 mm glass (though I could not say whether it is tempered or not.
Reply With Quote
  #8  
Old 01-09-2012, 01:13 PM
rstar's Avatar
rstar rstar is offline
Member
 
Join Date: Aug 2008
Location: Rosetown, SK
Posts: 275
rstar is on a distinguished road
Default

Thanks for the advice guys, I feel much better about it now, and it is 10mm glass, I measured from the sanded edge and it doesnt account for the slight bevel too the glass.
__________________
"120 Gallon - Fastest Build in the West"
20Gal Sump, 2x 250 PFO Metal Hallides running 2 20k XM Bulbs, 2X54 HOT5 1 KZ Coral Light 1 Fiji Purple, Euroreef RS 100 Skimmer, Quiet One 6000 Return Pump, 2X Tunze 6025, Nano Wavebox
~To Live Is To Reef~
Reply With Quote
Reply


Posting Rules
You may not post new threads