Default Overflow

I am in the process of building my first marine tank. I have decided to drill My tank for an overflow. My question is that when the manufacturers state the maximum overflow rate, are they including all of the drains. Example: Eshopps Eclipse L says maximum 1000 GPH. Does that mean all 3 drains total?
Reply With Quote
  #2  
Old 10-14-2021, 02:16 AM
arge arge is offline
Junior Member
 
Join Date: Aug 2019
Location: yvr
Posts: 3
arge is on a distinguished road
Default

The 3 drain overflow is known as a "Bean Animal" the main drain is a full siphon the 2nd drain is a open channel and only has a trickle of water entering it, the 3rd drain is emergency only and remains dry under normal operation.The 1000 gph rating would be for the main drain.


This video explains it well https://www.youtube.com/watch?v=RJQM...cMarineSystems