Default Let's see your Neptune AC program

Just picked one up and starting to learn the language - here is what I have so far - if you want to show your program - that would be great for me and others learning...

I am still trying to figure out some parameters (i.e. PH in the reactor)????
----------------------------


T5z$-A1
MHz$-A2
ATO&-A3
FAN&-A4
HET%-A5
CO2&-A6
ALM&-C1
MNL$-A8

If Time > 10:30 Then T5z ON
If Time > 22:00 Then T5z OFF
If Time > 10:30 Then MHz ON
If Time > 12:00 Then MHz OFF
If Time > 14:15 Then MHz ON
If Time > 15:45 Then MHz OFF
If Time > 18:30 Then MHz ON
If Time > 20:00 Then MHz OFF
If Time > 22:00 Then MNL ON
If Time > 10:30 Then MNL OFF
If Time > 09:00 Then ATO ON
If Time > 09:10 Then ATO OFF
If Time > 22:00 Then ATO ON
If Time > 22:10 Then ATO OFF
If Temp > 79.0 Then FAN ON
If Temp < 78.0 Then FAN OFF
If Temp < 76.0 Then HET ON
If Temp > 78.0 Then HET OFF

If Temp > 83.0 Then ALM ON
If Temp < 75.0 Then ALM ON
Reply With Quote
 


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 08:46 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.