probe start is for ballast with out starters, the ballast sends open current to the bulb and lets it go, if you have a pulse start, electric or HQI ballast they will not allow open current to the bulb so the probe cannot start the bulb. so in thoes cases you are relying on the starter of the ballast to start the arc in the bulb.

Steve
__________________
*everything said above is just my opinion, and may or may not reflect the views of this BBS, its Operators, and its Members. If cornered on any “opinion” I post I will totally deny having ever said this in a Court of Law…Unless I am the right one*