Quote:
Originally Posted by htfn View Post
OK so maxi-jet 1200 is not enough flow. I guess I searched wrong place then. Do you think flow rate should be more than 350g/hr?
I honestly don't think you need anymore than that. The problem I had with TLF is the inlet and outlet, TLF comes with 1/2 inch barb hose but for pellets you need 5/8 or even 3/4 barbs so you can get the flow that you need without grenade the reactor. If I were you I would really look into a smr1 or a vertex reactor. If thats not an option, try to find some thing used. All else fails, throw a bigger pump on it and make sure you remove the foam in the TLF, re-tap the barb fitting so you can put a larger diameter hose an try again. Be patient and let I run for awhile. I have had very good results with running the pellets. The smr1 with the pump costed me around less than 200 with tax.