Quote:
Originally Posted by The Grizz
Well it isnt you
|
You asked for input you dork.
Quote:
I have a closed loop on the 165 now and I dont like it because sand gets into the suction side and has damaged my 4way drum to the point that I cant use it until I replace it.
|
Well that's just really poor design.
Input should be up high or I've seen some people put them in the overflow box.
Quote:
Not to mention the noise of a hammerhead pump terrible, also had one of these on my 165 and I could hear it up stairs in my bedroom. This is a low noise, low power consumption build.
|
I think you will be disappointed in the flow of the DC10000 for the OMs. Or do you plan to add powerheads?
Quote:
ATO will have sensor in the smaller side to monitor the level and top it up balancing them both.
|
This sounds too complicated for me. What is the reason for two return chambers? Is there a reason to
not use one return chamber? I don't understand the benefit.