Is my ozone generator dead?
1) I measure the ORP on 2 cups of SW in a measuring cup at 416.
2) I bubble room air through an airstone for 5 minutes with no change to the ORP
3) I pass room air through my ozone gen, thn through the airstone into the cup of SW for 5 minutes...no change to ORP.
Do you think this test confirms that my ozone generator is no longer doing anything?
__________________
400 gal reef. Established April, 2007. 3 Sequence Dart, RM12-4 skimmer, 2 x OM4Ways, Yellow Tang, Maroon Clown (pair), Blonde Naso Tang, Vlamingi Tang, Foxface Rabbit, Unicorn Tang, 2 Pakistani Butterflies and a few coral gobies
My Tank: http://www.canreef.com/vbulletin/showthread.php?t=28436
Last edited by untamed; 02-08-2011 at 04:25 AM.
|