Quote:
Originally Posted by mrhasan View Post
Steven (sphelps) will probably be able to give a more firm insight on this.
An interesting math/science problem for young students would be to prove an unlevel tank would actually apply less pressure to the vertical panes of glass regardless of the angle. The highest pressure on vertical panes occurs when the tank is level, so aside from the obvious this type of failure mode can't be caused by an unlevel stand/floor.

Tank builders should consider offering an option to hydrotest large custom tanks to at least 1.5x design. It's a simple test that would add significant value by virtually ensuring the tank is free of defects capable of causing premature failures like this. For example I know my tank sitting a 1/3 full will never break as it was tested to 3x that. Personally I'll never setup a large tank again without similar assurance.