View Single Post
  #4  
Old 06-15-2014, 07:54 PM
Doug's Avatar
Doug Doug is offline
Rest In Peace
 
Join Date: Aug 2001
Location: Kamloops BC
Posts: 4,920
Doug has disabled reputation
Default

Quote:
Originally Posted by whatcaneyedo View Post
Without knowing how the ATO was done in the video that you watched I cannot know if its the same as a Tunze or not. Perhaps post a link to the video.

Here is my ATO program. Switch 4 and 1 are float sensors in the sump and Switch 3 is a water on the floor sensor. The ATO pump comes on when the sump switches are in the down position and runs for at least 30 seconds at a time. Its nothing special and there are other ways of doing it. The comprehensive users manual available on Neptune's site outlines a different method.

Set ON
Min Time 000:30 Then ON
If Sw4 OPEN Then OFF
If Sw1 OPEN Then OFF
If Sw3 CLOSED Then OFF

Outlets are numbered from left to right, top row and then lower row like this:
1234
5678
The video showed similar to you. I would guess the Osmolator has a separate controller you cannot program the float switches and sensor separate.

I understand the 1234
5678 as thats the same as my reefkeeper . I cant find it listed that way on computer though. Think I read and watched a hundred things by now.
__________________
Doug
Reply With Quote