View Single Post
  #29  
Old 09-29-2018, 06:54 PM
scherzo's Avatar
scherzo scherzo is offline
Member
 
Join Date: May 2009
Location: Coquitlam
Posts: 243
scherzo is on a distinguished road
Default

I had multiple problems too. Apparently forums everywhere people are reporting issues.

I had sensor #2 fail - they replaced it.
Then my PMUP went bad - had it replaced.

Working now for 2 weeks -s that is good.

I think if I ever have my sensors replaced I might put some silicone on the back of it where the wire enters the sensor. I did this with my old DIY float switch ATO that ran for 8 years. It may be a point of failure.

The PMUP might be a bad design - so if it fails again (if I reach outside of my warranty period) I'll just rig up a different pump. But then essentially I'd be only using the ATK for the optical sensor.

It is frustrating - thousands of dollars spent on the Apex system - pretty happy over the 8/9 years I've had it - but has not been a smooth experience for the ATK.
Reply With Quote