The 1.25" pipe goes all the way through (it's one piece) and acts as the secondary or back up drain. It's supported inside the 2" pipe by the bushing.

The primary drain is created by the 2" pipe. Water flows in between the 2" and 1.25" pipe and then through the gate valve. The gate valve is used to match the flow rate to the return pump and adjust the water level in the overflow box to just below the top of the 1.25" pipe. It's just like a standard herbie but the back up drain is inside the primary.