View Single Post
  #27  
Old 02-02-2014, 08:11 PM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

I don't want anyone to be mislead by my previous post as my diagnosis was incorrect. It has nothing to do with the cartridge sealing gasket

What 1eyedjyde said makes perfect sense
Quote:
Originally Posted by 1eyedjyde View Post
... Not sure how your sump is laid out but if you can move the inlet pump as far away from your drain line that would at least eliminate air entering through the pump.
but I ignored it as my pumps are in my last chamber and I've never had air going through either my return or my chiller

After days of still getting air in the reactors I think I've found the issue.
My pumps were quite close to the last baffle and it looks like they've been picking up micro bubbles. It was never an issue with the TLF150s as any air introduced can burp out on it's own, but the 'RO' style canisters trap any introduced air which then builds, and builds and ...
I had to use a flashlight with my sump room lights off to spot the bubbles

I've moved the pumps as far as possible away from the baffle and hope to report back that the issue is solved. I'll give it a couple days before I do so

I'm loving this reactor style for ease of use, and in my case the spread through the media is far superior to that of the TLF150s
Reply With Quote